Literature DB >> 33474990

LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community.

Taylor J Moehling1, Gihoon Choi1, Lawrence C Dugan2, Marc Salit3, Robert J Meagher1.   

Abstract

Introduction: Over the past decade, loop-mediated isothermal amplification (LAMP) technology has played an important role in molecular diagnostics. Amongst numerous nucleic acid amplification assays, LAMP stands out in terms of sample-to-answer time, sensitivity, specificity, cost, robustness, and accessibility, making it ideal for field-deployable diagnostics in resource-limited regions.Areas covered: In this review, we outline the front-end LAMP design practices for point-of-care (POC) applications, including sample handling and various signal readout methodologies. Next, we explore existing LAMP technologies that have been validated with clinical samples in the field. We summarize recent work that utilizes reverse transcription (RT) LAMP to rapidly detect SARS-CoV-2 as an alternative to standard PCR protocols. Finally, we describe challenges in translating LAMP from the benchtop to the field and opportunities for future LAMP assay development and performance reporting.Expert opinion: Despite the popularity of LAMP in the academic research community and a recent surge in interest in LAMP due to the COVID-19 pandemic, there are numerous areas for improvement in the fundamental understanding of LAMP, which are needed to elevate the field of LAMP assay development and characterization.

Entities:  

Keywords:  Loop-mediated isothermal amplification; SARS-CoV-2; diagnostics; point-of-care

Year:  2021        PMID: 33474990     DOI: 10.1080/14737159.2021.1873769

Source DB:  PubMed          Journal:  Expert Rev Mol Diagn        ISSN: 1473-7159            Impact factor:   5.225


  25 in total

1.  Highly Sensitive Detection of Human Pluripotent Stem Cells by Loop-Mediated Isothermal Amplification.

Authors:  Ryota Yasui; Atsuka Matsui; Keisuke Sekine; Satoshi Okamoto; Hideki Taniguchi
Journal:  Stem Cell Rev Rep       Date:  2022-06-03       Impact factor: 5.739

2.  Saliva "Treat-and-Heat" Triplex Reverse Transcription Loop-Mediated Isothermal Amplification Assay for SARS-CoV-2.

Authors:  Marie J Y Reolo; Carlos S R Eleazar; Joseph P Sonio; Ryonne T Solon; Janika L B Villamor; Alexandra K Loedin; Keith J M Moore
Journal:  J Biomol Tech       Date:  2021-09

3.  Corona Detective: a simple, scalable, and robust SARS-CoV-2 detection method based on reverse transcription loop-mediated isothermal amplification.

Authors:  Guy Aidelberg; Rachel Aronoff; Tatiana Eliseeva; Francisco Javier Quero; Hortense Vielfaure; Martin Codyre; Kathrin Hadasch; Ariel B Lindner
Journal:  J Biomol Tech       Date:  2021-09

Review 4.  Loop-Mediated Isothermal Amplification Detection of SARS-CoV-2 and Myriad Other Applications.

Authors:  Keith J M Moore; Jeremy Cahill; Guy Aidelberg; Rachel Aronoff; Ali Bektaş; Daniela Bezdan; Daniel J Butler; Sridar V Chittur; Martin Codyre; Fernan Federici; Nathan A Tanner; Scott W Tighe; Randy True; Sarah B Ware; Anne L Wyllie; Evan E Afshin; Andres Bendesky; Connie B Chang; Richard Dela Rosa; Eran Elhaik; David Erickson; Andrew S Goldsborough; George Grills; Kathrin Hadasch; Andrew Hayden; Seong-Young Her; Julie A Karl; Chang Hee Kim; Alison J Kriegel; Thomas Kunstman; Zeph Landau; Kevin Land; Bradley W Langhorst; Ariel B Lindner; Benjamin E Mayer; Lee A McLaughlin; Matthew T McLaughlin; Jenny Molloy; Christopher Mozsary; Jerry L Nadler; Melinee D'Silva; David Ng; David H O'Connor; Jerry E Ongerth; Olayinka Osuolale; Ana Pinharanda; Dennis Plenker; Ravi Ranjan; Michael Rosbash; Assaf Rotem; Jacob Segarra; Stephan Schürer; Scott Sherrill-Mix; Helena Solo-Gabriele; Shaina To; Merly C Vogt; Albert D Yu; Christopher E Mason
Journal:  J Biomol Tech       Date:  2021-09

5.  Filtration-assisted magnetofluidic cartridge platform for HIV RNA detection from blood.

Authors:  Alexander Y Trick; Hoan Thanh Ngo; Anju H Nambiar; Marisa M Morakis; Fan-En Chen; Liben Chen; Kuangwen Hsieh; Tza-Huei Wang
Journal:  Lab Chip       Date:  2022-03-01       Impact factor: 7.517

6.  Fast Detection of SARS-CoV-2 RNA Directly from Respiratory Samples Using a Loop-Mediated Isothermal Amplification (LAMP) Test.

Authors:  Olympia E Anastasiou; Caroline Holtkamp; Miriam Schäfer; Frieda Schön; Anna Maria Eis-Hübinger; Andi Krumbholz
Journal:  Viruses       Date:  2021-04-29       Impact factor: 5.048

Review 7.  Loop-Mediated Isothermal Amplification (LAMP) as a Promising Point-of-Care Diagnostic Strategy in Avian Virus Research.

Authors:  Faiz Padzil; Abdul Razak Mariatulqabtiah; Wen Siang Tan; Kok Lian Ho; Nurulfiza Mat Isa; Han Yih Lau; Jalila Abu; Kuo-Pin Chuang
Journal:  Animals (Basel)       Date:  2021-12-30       Impact factor: 2.752

8.  Rapid and sensitive detection of potato cyst nematode Globodera rostochiensis by loop-mediated isothermal amplification assay.

Authors:  Amit Ahuja; Vijay Joshi; Gagandeep Singh; Artha Kundu; Chaitra G Bhat; Satya Kumar; Uma Rao; Vishal Singh Somvanshi
Journal:  3 Biotech       Date:  2021-05-24       Impact factor: 2.893

9.  End-User Perspectives on Using Quantitative Real-Time PCR and Genomic Sequencing in the Field.

Authors:  Kyle Parker; Jonathan Forman; George Bonheyo; Brittany Knight; Rachel Bartholomew; Richard Ozanich; Kenneth B Yeh
Journal:  Trop Med Infect Dis       Date:  2022-01-05

10.  Comparative Diagnostic Performance of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Kit for the Rapid Detection of SARS-CoV-2.

Authors:  Alexander Domnich; Andrea Orsi; Donatella Panatto; Vanessa De Pace; Valentina Ricucci; Patrizia Caligiuri; Giulia Guarona; Valerio Chessa; Diego Ferone; Simona Boccotti; Bianca Bruzzone; Giancarlo Icardi
Journal:  Pathogens       Date:  2021-12-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.