| Literature DB >> 33470391 |
Jingyang Zeng1, Sijie Zhang2, Qilin Wu2, Shunyuan Li1, Yingle Chen1, Biyu Wu3.
Abstract
Although some investigations have been performed to determine the effects of transfusion load and suction pressure on renal function during intraoperative salvage autotransfusion, the precise threshold is still undetermined. A total of 625 patients undergoing surgery with the Continuous AutoTransfusion System (CATSplus) were enrolled and divided into groups according to the utilized suction pressure and transfusion volume. Plasma free hemoglobin (FHB) and creatinine clearance (CCr) were assayed to indicate the renal function. Both 0.03 MPa suction (≥4-unit load) and >5 units transfusion changed the levels of FHB and CCr significantly when measured 24 h post-operation compared to pre-operation. Under 0.02 MPa suction (≥4-unit load), the alteration of FHB and CCr returned to normal after 24 h. Under 3 units transfusion, the levels of FHB and CCr at 6 and 12 h post-operation changed significantly compared to pre-operation (P<0.05 or P<0.01, respectively), and this alteration could be restored to normal at 72 h post-operation. After an exhaustive investigation, less than 4 units transfusion and less than 0.03 MPa suction pressure are recommended for intraoperative salvage autotransfusion.Entities:
Mesh:
Year: 2021 PMID: 33470391 PMCID: PMC7812910 DOI: 10.1590/1414-431X202010292
Source DB: PubMed Journal: Braz J Med Biol Res ISSN: 0100-879X Impact factor: 2.590