Literature DB >> 33461722

High-defined quantitative snapshots of the ganglioside lipidome using high resolution ion mobility SLIM assisted shotgun lipidomics.

Kelly L Wormwood Moser1, Gregory Van Aken1, Daniel DeBord1, Nathan Galen Hatcher2, Laura Maxon1, Melissa Sherman1, Lihang Yao2, Kim Ekroos3.   

Abstract

Defects in sphingolipid metabolism have emerged as a common link across neurodegenerative disorders, and a deeper understanding of the lipid content in preclinical models and patient specimens offers opportunities for development of new therapeutic targets and biomarkers. Sphingolipid metabolic pathways include the formation of glycosphingolipid species that branch into staggeringly complex structural heterogeneity within the globoside and ganglioside sub-lipidomes. Characterization of these sub-lipidomes has typically relied on liquid chromatography-mass spectrometry-based (LC-MS) approaches, but such assays are challenging and resource intensive due to the close structural heterogeneity, the presence of isobaric and isomeric species, and broad dynamic range of endogenous glycosphingolipids. Here, we apply Structures for Lossless Ion Manipulations (SLIM)-based High Resolution Ion Mobility (HRIM)-MS to enable rapid, repeatable, quantitative assays with deep structural information sufficient to resolve endogenous brain gangliosides at the level of individual molecular species. Analyses were performed using a prototype SLIM-MS instrument equipped with a 13-m serpentine path which enabled resolution of closely related isomeric analytes such as GD1a d36:1 and GD1b d36:1 based on recorded mass-to-charge (m/z) and arrival times. To demonstrate the power of our methodology, brain extracts derived from wild-type mice hemi-brains were analyzed by HRIM-MS using flow injection analyses (FIA) without the need for additional separation by liquid chromatography. Endogenous ganglioside species were readily resolved, identified, and quantified by FIA-SLIM-MS analyses within 2 min per sample. Thus, the FIA-SLIM-MS platform enables robust quantification across a broad range of lipid species in biological specimens in a standardized assay format that is readily scalable to support studies with large sample numbers.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Gangliosides; High resolution ion mobility; Isomers; Lipidomics; Mass spectrometry

Mesh:

Substances:

Year:  2020        PMID: 33461722     DOI: 10.1016/j.aca.2020.12.022

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

1.  Insights and prospects for ion mobility-mass spectrometry in clinical chemistry.

Authors:  David C Koomen; Jody C May; John A McLean
Journal:  Expert Rev Proteomics       Date:  2022-01-17       Impact factor: 3.940

2.  Structural characterization and analysis of different epimers of neutral glycosphingolipid LcGg4 by ion mobility spectrometry-mass spectrometry.

Authors:  Tianqi Gao; Aneirin A Lott; Fanran Huang; Rajendra Rohokale; Qingjiang Li; Hernando J Olivos; Sixue Chen; Zhongwu Guo
Journal:  Analyst       Date:  2022-06-27       Impact factor: 5.227

3.  Rapid Discrimination of Citrus reticulata 'Chachi' by Electrospray Ionization-Ion Mobility-High-Resolution Mass Spectrometry.

Authors:  Juan Liu; Keke Wang; Yuling Li; Bowen Zhou; Kuofeng Tseng; Xiaoqiang Zhang; Yue Su; Wenjian Sun; Yinlong Guo
Journal:  Molecules       Date:  2021-11-20       Impact factor: 4.411

4.  Lipid analysis by ion mobility spectrometry combined with mass spectrometry: A brief update with a perspective on applications in the clinical laboratory.

Authors:  Joshua A Dubland
Journal:  J Mass Spectrom Adv Clin Lab       Date:  2021-12-13

5.  Validation of a multiplexed and targeted lipidomics assay for accurate quantification of lipidomes.

Authors:  Nanyan Rena Zhang; Nathan G Hatcher; Kim Ekroos; Komal Kedia; Monika Kandebo; Jacob N Marcus; Sean M Smith; Kevin P Bateman; Daniel S Spellman
Journal:  J Lipid Res       Date:  2022-04-27       Impact factor: 6.676

6.  Collision Cross-Section Calibration Strategy for Lipid Measurements in SLIM-Based High-Resolution Ion Mobility.

Authors:  Bailey S Rose; Jody C May; Allison R Reardon; John A McLean
Journal:  J Am Soc Mass Spectrom       Date:  2022-06-02       Impact factor: 3.262

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.