Literature DB >> 33461710

Detection of a novel glycodelin biomarker using electrochemical immunosensor for endometriosis.

Thangapandi Kalyani1, Amalesh Nanda1, Saikat Kumar Jana2.   

Abstract

Endometriosis is one of the important issues in women worldwide, which decreases the quality of women's lives in their reproductive age. The diagnosis of endometriosis is carried out by the invasive procedure, which is expensive and painful. In the last few decades, researchers have given more attention to constructing a suitable biomarker-based biosensor for semi/non-invasive diagnosis of endometriosis. As a result, glycodelin (GLY) was found as a promising biomarker because of its selectivity and sensitivity. To the best of our knowledge, it was the first study that reported the detection of GLY biomarker using an electrochemical immunosensor. Briefly, a label-free electrochemical immunosensing platform was constructed through in-situ surface modification of cysteamine layer and immobilisation of antibody (anti-GLY) with help of glutaraldehyde. The interaction between antigen and antibody was measured using square wave voltammetry (SWV). The SWV signal could decrease proportionally with the increasing GLY concentration ranging from 1 to 1000 ng mL-1 (R2 = 0.9981) and a detection limit (LOD) of 0.43 ng mL-1. Moreover, an immunosensor could exhibit high sensitivity, selectivity, long-term stability, reproducibility and regeneration. Accuracy of the immunosensor was compared with enzyme-linked immunosorbent assay (ELISA), and satisfying results were obtained. The detection of GLY biomarker may be a new possibility for endometriosis diagnosis.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cysteamine; Endometriosis; Glycodelin; Immunosensor; Label-free

Mesh:

Substances:

Year:  2020        PMID: 33461710     DOI: 10.1016/j.aca.2020.11.015

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Electrochemical Immunoassay for Tumor Marker CA19-9 Detection Based on Self-Assembled Monolayer.

Authors:  Zheng Wei; Xiaoping Cai; Weifeng Cui; Junping Zhang
Journal:  Molecules       Date:  2022-07-18       Impact factor: 4.927

Review 2.  Use of Cysteamine and Glutaraldehyde Chemicals for Robust Functionalization of Substrates with Protein Biomarkers-An Overview on the Construction of Biosensors with Different Transductions.

Authors:  Rodica Elena Ionescu
Journal:  Biosensors (Basel)       Date:  2022-07-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.