Literature DB >> 33460601

Standardized Measurement of Femoral Artery Depth by Computed Tomography to Predict Vascular Complications After Transcatheter Aortic Valve Implantation.

Eric Durand1, Maryline Penso2, Thibault Hemery2, Thomas Levesque2, Gustavo Moles2, Christophe Tron2, Najime Bouhzam2, Nicolas Bettinger2, Stephanie Wong3, Jean-Nicolas Dacher3, Hélène Eltchaninoff2.   

Abstract

Vascular complications (VCs) are difficult to predict and remain an important issue after transfemoral (TF) transcatheter aortic valve implantation (TAVI) although their incidence has decreased with size reduction of introducers. We aimed to evaluate a standardized measurement of femoral artery depth (FAD) using computed tomography (CT) to predict VCs after TAVI. We performed a retrospective study of 679 TF TAVI patients. We evaluated a standardized CT method to measure FAD immediately above the bifurcation. Sheath-to-femoral-artery ratio (SFAR), calcification, and tortuosity were also evaluated. VCs were defined by the Valve Academic Research Consortium (VARC)-2. Receiver operating characteristic (ROC) curves were used to predict major VCs and the need for a stent-graft. The median values of FAD and SFAR were 49.0 (36.2 to 66.7) mm and 0.95 (0.81 to 1.18), respectively. Major VCs occurred in 37 (5.4%) patients and a stent-graft was required in 49 (7.1%) patients. FAD predicted the need for a stent-graft [0.61 (0.51 to 0.70), p = 0.04] but not major VCs [0.52 (0.40 to 0.63), p = 0.76]. In contrast, SFAR did not predict the need for a stent-graft [0.53 (0.43 to 0.62), p = 0.61] but predicted major VCs [0.70 (0.58 to 0.81), p = 0.001]. Calcification and tortuosity predicted neither major VCs nor the need for a stent-graft. In conclusion, the results of our study suggest that CT measurements of FAD and SFAR provide additional information to predict major VCs and the need for a femoral stent-graft after TF TAVI.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Year:  2021        PMID: 33460601     DOI: 10.1016/j.amjcard.2020.12.089

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  1 in total

1.  TAVI-CT score to evaluate the anatomic risk in patients undergoing transcatheter aortic valve implantation.

Authors:  Nicola Corcione; Alberto Morello; Paolo Ferraro; Michele Cimmino; Michele Albanese; Martino Pepe; Palma Luisa Nestola; Salvatore Giordano; Luca Bardi; Giuseppe Biondi-Zoccai; Arturo Giordano
Journal:  Sci Rep       Date:  2022-05-09       Impact factor: 4.996

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.