Literature DB >> 33457214

Is robot-assisted partial nephrectomy safe for high complexity tumors?

Periklis Koukourikis1, Ali Abdullah Alqahtani1, Koon Ho Rha1.   

Abstract

Entities:  

Year:  2020        PMID: 33457214      PMCID: PMC7807312          DOI: 10.21037/tau-20-836

Source DB:  PubMed          Journal:  Transl Androl Urol        ISSN: 2223-4683


× No keyword cloud information.
Nephron-sparing surgery (NSS) is the treatment of choice for cT1 kidney tumors as it provides similar oncological safety in comparison with radical nephrectomy with the advantage of preservation of renal function and improved overall survival (1). In the minimally invasive era, robot-assisted partial nephrectomy (RAPN) has gained great popularity, when compared with open or laparoscopic-assisted NSS, as it offers similar oncological results with better perioperative outcomes (2,3). Furthermore, the robotic approach offers to surgeon three-dimensional (3-D) visualization of the operative field, improved dexterity as well as precision of movements resulting in a shorter learning curve. RAPN has become the preferred approach over laparoscopic-assisted partial nephrectomy even for large and complicated tumors. The article by Buffi et al., which was published in a recent issue of European Urology, explored the outcomes of RAPN in patients with complex renal tumors (PADUA score ≥10) and compared the observed outcomes between patients with increasing complexity. The authors, also, described the use of the latest induced technologies in RAPN, such as the TilePro technology, near-infrared fluorescence (NIRF) imaging, and hyperaccuracy 3-D (HA3D) reconstruction. In their retrospective analysis, they included 225 patients, and the surgeries were performed in four different tertiary centers over a period of 7 years. Within the cohort, 111 patients had a PADUA score of 10, 85 patients had a PADUA score of 11, while 45 and 14 patients had a PADUA score of 12 and 13, respectively. The authors have correctly identified the lack of large, multi-institutional studies in the literature assessing the outcomes of RAPN in patients with highly complex tumors and attempted to elucidate this specific field. The primary outcome of this study was the reporting of the outcomes of RAPN in the selected patient population. The approach was transperitoneal in 186 (72.9%) patients and retroperitoneal in 69 patients (27.1%) and the median operative time was 159 (IQR: 120–210) minutes. The type of ischemia was main artery clamping to the majority of patients, while selective clamping and zero ischemia were also used (70.4% vs. 16.5% vs. 5.1%, respectively). A median estimated blood loss of 150 (IQR: 100–250) mL and a median warm ischemia time (WIT) of 18 (IQR: 15–23) were noted. Authors reported a Clavien-Dindo >2 complication in 13 (5.1%) patients, while positive surgical margins (PSMs) were observed in 4 patients (1.9% of patients with malignant histology), and the conversions to open surgery and radical nephrectomy were 4 (1.6%) and 5 (1.9%), respectively. An additional outcome was the achievement of optimal surgical outcomes, which was defined according to the Margin Ischemia and Complication (MIC) binary system (absence of Clavien-Dindo >2 complications, WIT <20 min, and absence of PSMs) (4). Overall, optimal surgical outcomes were achieved in 158 (62%) patients. Regarding tumors with the highest complexity, the results showed a significantly lower rate of MIC achievement in tumors of PADUA score 12–13 compared to tumors of PADUA score 10 and PADUA score 11, 40.7%, 68.5%, and 68.2%, respectively (P=0.001). Independent predictors of not achieving MIC in multivariate analysis were PADUA score 12–13 and male gender. These results are in line with previous studies; in a large single institutional series, the rate of optimal surgical outcomes was decreasing through the patients as the PADUA complexity score was increasing, from 65.3% and 56.9% for patients with low and intermediate complexity tumors to 37.5% for patients with high complexity tumors (5). In a recent paper, Takahara et al. noted a lower rate of optimal surgical outcomes achievement in the high-complexity group (PADUA ≥10) of patients compared to non-high-complexity group (68.3% vs. 86.3%, respectively, P=0.009) (6). Taking into account the three different outcomes included in MIC achievement between the groups of patients, in this analysis, the main cause of failure for optimal surgical outcomes was increased (>20 minutes) WIT. WIT was 21 (IQR: 18–27) minutes in patients with PADUA 12–13 compared to 17 (IQR: 14–21) minutes in patients with PADUA 10 (P<0.001), with more patients at highest complexity group having a WIT >20 min (39.7% vs. 15.7%, P=0.015, PADUA 12–13 vs. PADUA 10, respectively). On the other hand, no significant difference was found between the groups of patients with lower and higher complexity tumors on PSMs and major complications (Clavien-Dindo >2) rates. WIT remains a topic of interest and debate in the literature, as the duration of ischemia is the only modifiable surgical factor affecting kidney function preservation, while the other factors are patient-depended and unmodifiable (age, preoperative renal function, comorbidities). A proposed acceptable time limit is 20–30 minutes, but most authors agree that it is not a binary outcome and that every minute counts during hilar clamping (7,8). Previous data, also, support the correlation between high PADUA score and increased WIT (9,10). The prolongation of ischemia duration seems a natural consequence during RAPN in complicated tumors as the reconstruction of the large collecting system and renal parenchyma defect have to be performed meticulously to avoid complications such hemorrhage and urine leakage. We have to move beyond WIT analysis, studies support that prolonged WIT has a negative impact on functional outcomes, although they have focused mainly in the short-term period (11). We support the idea that WIT has only a minor effect in long-term functional outcomes in patients with a normal contralateral kidney. The results of our series showed that neither WIT nor the method of clamping significantly affects the estimated glomerular filtration rate (eGFR) in a long-term period of follow-up (5,12). Even in cases of extreme WIT prolongation (30–60 min) there are data to support the mild structural changes on human kidney and the minimum effect on long-term functional outcomes (13,14). Authors choose to use the MIC achievement, which is a standardized system for reporting optimal surgical outcomes for NSS, to report and compare their results. However, this system does not include analysis of long-term functional outcomes and a separate analysis of how the difference in WIT between the groups of patients affected the long-term functional outcomes were not performed in this study. Recently, a new system of trifecta outcomes reporting for RAPN was published by Brassetti et al., which excludes WIT and includes postoperative eGFR reduction (15). This new reporting system could be more suitable for assessing RAPN outcomes in series where different techniques for hilar clamping are used, such as selective artery clamping or zero ischemia. We must be grateful to authors for presenting the use of novel technologies, undoubtedly they are of great importance for assisting the surgeon to perform more complex cases. However, authors did not report the impact of the use of these techniques on perioperative outcomes and MIC achievement in this cohort. Also, always we have to bear in mind the economic impact for their use and difficulties adopting them in everyday practice. In our clinical practice, as in most institutions performing RAPN, the use of intraoperative laparoscopic ultrasound combined with TilePro technology is essential for almost every RAPN. Furthermore, we have previously described a simplified zero ischemia technique using kidney donor computed tomographic angiography, TilePro and conventional laparoscopic bulldog clamps, which is an easily adopted technique without special requirements (16). We believe that the use of novel technologies should be further assessed and validated in future prospective and ideally randomized studies, evaluating the oncological and the functional outcomes of RAPN. The present study encounters some limitations. The retrospective nature of this study is a major drawback, albeit we have to admit that the inclusion of patients from different institutions increased the external validity of the study. The lack of definite inclusion criteria between different surgeons induced selection bias and the use of different surgical techniques and technologies during the period of study increase the heterogeneity, and authors have recognized it. The median follow-up period was relatively short (28 months) for oncological outcomes reporting; this period of follow-up is adequate for long-term functional outcomes reporting, whereas authors did not include this outcome in the analysis. RAPN is a feasible and effective treatment, when performed by experienced surgeons in accordance with the use of the novel technologies, even for the most challenging cases. However, in tumors with the highest complexity (PADUA 12–13), the surgical outcomes may be suboptimal and proper patient counseling should be given. In light of these promising results, there are indications that the high-risk group suggested by PADUA classification seems to be not a single category. Further studies are needed to define the proper risk stratification and assessment of oncological and functional outcomes to safely extend the indications for RAPN. The article’s supplementary files as
  16 in total

1.  Margin, ischemia, and complications (MIC) score in partial nephrectomy: a new system for evaluating achievement of optimal outcomes in nephron-sparing surgery.

Authors:  Nicolòmaria Buffi; Giuliana Lista; Alessandro Larcher; Giovanni Lughezzani; Vincenzo Ficarra; Andrea Cestari; Massimo Lazzeri; Giorgio Guazzoni
Journal:  Eur Urol       Date:  2012-06-09       Impact factor: 20.096

2.  Outcomes of high-complexity renal tumours with a Preoperative Aspects and Dimensions Used for an Anatomical (PADUA) score of ≥10 after robot-assisted partial nephrectomy with a median 46.5-month follow-up: a tertiary centre experience.

Authors:  Ali Abdel Raheem; Atalla Alatawi; Dae K Kim; Abulhasan Sheikh; Ibrahim Alabdulaali; Woong K Han; Young D Choi; Koon H Rha
Journal:  BJU Int       Date:  2016-05-26       Impact factor: 5.588

3.  The Synergistic Influence of Ischemic Time and Surgical Precision on Acute Kidney Injury After Robotic Partial Nephrectomy.

Authors:  Julien Dagenais; Matthew J Maurice; Pascal Mouracade; Onder Kara; Ryan J Nelson; Ercan Malkoc; Jihad H Kaouk
Journal:  Urology       Date:  2017-03-16       Impact factor: 2.649

Review 4.  Partial nephrectomy versus radical nephrectomy for clinical localised renal masses.

Authors:  Frank Kunath; Stefanie Schmidt; Laura-Maria Krabbe; Arkadiusz Miernik; Philipp Dahm; Anne Cleves; Mario Walther; Nils Kroeger
Journal:  Cochrane Database Syst Rev       Date:  2017-05-09

5.  Renal function is the same 6 months after robot-assisted partial nephrectomy regardless of clamp technique: analysis of outcomes for off-clamp, selective arterial clamp and main artery clamp techniques, with a minimum follow-up of 1 year.

Authors:  Christos Komninos; Tae Young Shin; Patrick Tuliao; Woong Kyu Han; Byung Ha Chung; Young Deuk Choi; Koon Ho Rha
Journal:  BJU Int       Date:  2015-05-18       Impact factor: 5.588

6.  The impact of warm ischaemia on renal function after laparoscopic partial nephrectomy.

Authors:  Mihir M Desai; Inderbir S Gill; Anup P Ramani; Massimiliano Spaliviero; Lisa Rybicki; Jihad H Kaouk
Journal:  BJU Int       Date:  2005-02       Impact factor: 5.588

7.  Laparoscopic partial nephrectomy: effect of warm ischemia on serum creatinine.

Authors:  Sam B Bhayani; Koon H Rha; Peter A Pinto; Albert M Ong; Mohamad E Allaf; Bruce J Trock; Thomas W Jarrett; Louis R Kavoussi
Journal:  J Urol       Date:  2004-10       Impact factor: 7.450

8.  Surgical quality, cancer control and functional preservation: introducing a novel trifecta for robot-assisted partial nephrectomy.

Authors:  Aldo Brassetti; Umberto Anceschi; Riccardo Bertolo; Mariaconsiglia Ferriero; Gabriele Tuderti; Umberto Capitanio; Alessandro Larcher; Juan Garisto; Alessandro Antonelli; Alexander Mottire; Andrea Minervini; Paolo Dell'oglio; Alessandro Veccia; Daniele Amparore; Rocco S Flammia; Andrea Mari; Francesco Porpiglia; Francesco Montorsi; Jihad Kaouk; Riccardo Autorino; Marco Carini; Michele Gallucci; Giuseppe Simone
Journal:  Minerva Urol Nefrol       Date:  2019-12-12       Impact factor: 3.720

9.  The association between the anatomical features of renal tumours and the functional outcomes of robot-assisted partial nephrectomy.

Authors:  Jeong Woo Lee; Sung Yong Cho; Chanhoo Jeon; Kyungtae Ko; Hyeon Hoe Kim
Journal:  Can Urol Assoc J       Date:  2014-11       Impact factor: 1.862

10.  Simplified zero ischemia in robot assisted partial nephrectomy: initial yonsei experience.

Authors:  Tae Young Shin; Kyung Hwa Choi; Sey Kiat Lim; Kwang Hyun Kim; Dong Hoon Lee; Joo Yong Lee; Young Taik Oh; Dae Chul Jung; Woong Kyu Han; Koon Ho Rha
Journal:  Korean J Urol       Date:  2013-02-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.