Literature DB >> 33453796

An impedimetric biosensor system based on disposable graphite paper electrodes: Detection of ST2 as a potential biomarker for cardiovascular disease in human serum.

Burçak Demirbakan1, Mustafa Kemal Sezgintürk2.   

Abstract

In present study, we developed a highly sensitive, electrochemical immunosensor based on fullerene C60-modified disposable graphite paper (GP) electrode for determination of Suppression of Tumorigenicity 2 (ST2) in human serum. The synthesis of the ST2 immunosensor was monitored with electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) techniques and single frequency impedance (SFI) technique which is utilized for the specific interaction between anti-ST2 and ST2 antigen. Moreover, the morphological alteration of each GP surface was examined by scanning electron microscopy (SEM), SEM-energy dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM). All parameters such as fullerene C60 concentration, antibody concentration and antibody incubation time were optimized. Analytical characteristics such as linear determination range, repeatability, reproducibility, regeneration and surface coverage were determined for the immunosensor. The ST2 electrochemical immunosensor had excellent repeatability, reproducibility and a wide detection range (from 0.1 fg mL-1 to 100 fg mL-1). The proposed immunosensor also had low limit of detection (LOD) and limit of quantification (LOQ) values of 0.124 fg mL-1 and 0.414 fg mL-1, respectively. The proposed immunosensor was applied to real samples to test applicability in clinical practice.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Cardiovascular disease; Graphite paper (GP); Suppression of tumorigenicity 2 (ST2)

Mesh:

Substances:

Year:  2020        PMID: 33453796     DOI: 10.1016/j.aca.2020.12.001

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

Review 1.  Electroanalytical point-of-care detection of gold standard and emerging cardiac biomarkers for stratification and monitoring in intensive care medicine - a review.

Authors:  Robert D Crapnell; Nina C Dempsey; Evelyn Sigley; Ascanio Tridente; Craig E Banks
Journal:  Mikrochim Acta       Date:  2022-03-12       Impact factor: 6.408

2.  A high-performance electrochemical aptasensor based on graphene-decorated rhodium nanoparticles to detect HER2-ECD oncomarker in liquid biopsy.

Authors:  Mahdi Sadeghi; Soheila Kashanian; Seyed Morteza Naghib; Elham Arkan
Journal:  Sci Rep       Date:  2022-02-28       Impact factor: 4.996

Review 3.  Nanobioengineered Sensing Technologies Based on Cellulose Matrices for Detection of Small Molecules, Macromolecules, and Cells.

Authors:  Supratim Mahapatra; Vinish Ranjan Srivastava; Pranjal Chandra
Journal:  Biosensors (Basel)       Date:  2021-05-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.