Literature DB >> 33452540

Reliability of Stereophotogrammetry for Area Measurement in the Periocular Region.

Jinhua Liu1, Alexander C Rokohl1, Yongwei Guo2, Senmao Li1, Xiaoyi Hou1, Wanlin Fan1, Maxim Formuzal1, Ming Lin3, Ludwig M Heindl4,5.   

Abstract

Three-dimensional (3D) stereophotography area measurements are essential for describing morphology in the periocular region. However, its reliability has not yet been sufficiently validated. The objective of this study was to evaluate the reliability of 3D stereophotogrammetric area measurements in the periocular region. Forty healthy volunteers had five flat paper objects placed at each of the seven periocular positions including the endocanthion and the upper medial, upper middle, upper lateral, lower medial, lower middle, and the lower lateral eyelid. Two series of photographic images were captured twice by the same investigator. Each image of the first series was measured twice by the same rater, while images of both series were measured once by a second rater. Differences between these measurements were calculated, and the intrarater, interrater, and intramethod reliability was evaluated for intraclass correlation coefficients (ICCs), mean absolute differences (MADs), technical errors of measurements (TEMs), relative errors of measurements (REMs), and relative TEM (rTEM). Our results showed that 21.2% of all ICCs were considered as excellent, 45.5% were good, 27.3% were moderate, and 6.1% were poor. The interrater ICC for the endocanthion location was 0.4% on a low level. MAD values for all objects were less than 0.3 mm2, all TEM were less than 1 mm2, the REM and rTEM were less than 2% for all objects, showing high reliability. 3D stereophotogrammetry is a highly reliable system for periocular area measurements and may be used in the clinical routine for planning oculoplastic surgeries and for evaluating changes in periocular morphology.Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
© 2021. The Author(s).

Entities:  

Keywords:  Area measurements; Periocular region; Reliability; Three-dimensional stereophotography

Mesh:

Year:  2021        PMID: 33452540     DOI: 10.1007/s00266-020-02091-5

Source DB:  PubMed          Journal:  Aesthetic Plast Surg        ISSN: 0364-216X            Impact factor:   2.326


  2 in total

1.  Combination of Sclerotherapy and Dual-Wavelength Laser in the Management of Infantile Hemangiomas in Chinese Infants.

Authors:  Li Lin; Peng Guo; Yongqian Cao; Qiang Li; Jian Zhang; Ran Huo
Journal:  Dermatol Surg       Date:  2019-10       Impact factor: 3.398

2.  Validating three-dimensional imaging for volumetric assessment of periorbital soft tissue.

Authors:  Jonathan N Hyer; Fabiola Murta; Valerie A R Juniat; Daniel G Ezra
Journal:  Orbit       Date:  2020-01-14
  2 in total
  2 in total

1.  Reproducibility of Three-Dimensional Volumetric Measurement of Periocular Tumor Models.

Authors:  Yongwei Guo; Ludwig M Heindl; Wanlin Fan; Alexander C Rokohl; Patrick Kupka; Xiaoyi Hou; Jinhua Liu; Senmao Li; Adam Kopecky; Sitong Ju; Philomena A Wawer Matos
Journal:  Ophthalmol Ther       Date:  2022-10-16

2.  Validation of the Portable Next-Generation VECTRA H2 3D Imaging System for Periocular Anthropometry.

Authors:  Wanlin Fan; Yongwei Guo; Xiaoyi Hou; Jinhua Liu; Senmao Li; Sitong Ju; Philomena Alice Wawer Matos; Michael Simon; Alexander C Rokohl; Ludwig M Heindl
Journal:  Front Med (Lausanne)       Date:  2022-03-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.