Literature DB >> 33451814

Artificial Intelligence-Powered Measurement of Left Ventricular Ejection Fraction Using a Handheld Ultrasound Device.

Dominika Filipiak-Strzecka1, Jarosław D Kasprzak2, Paulina Wejner-Mik2, Ewa Szymczyk2, Katarzyna Wdowiak-Okrojek2, Piotr Lipiec2.   

Abstract

The aim of this study was to assess the accuracy of an algorithm for automated measurement of left ventricular ejection fraction (LVEF) available on handheld ultrasound devices (HUDs). One hundred twelve patients admitted to the cardiology department underwent assessment performed with an HUD. In each case, the four-chamber apical view was obtained, and LVEF was calculated with LVivo software. Subsequently, during the examination performed with the use of the stationary echocardiograph, the 3-D measurement of LVEF was recorded. The average LVEFs measured with LVivo and the 3-D reference method were 46 ± 14% and 48 ± 14%, respectively. The correlation between the measurements obtained with the HUD and 3-D evaluation was high (r = 0.92, 95% confidence interval: 0.87-0.95, p < 0.0001). The mean difference between the LVEF obtained with LVivo and the 3-D LVEF was not significant (mean difference: -0.61%, 95% confidence interval: -1.89 to 0.68, p = 0.31). The LVivo software despite its limitations is capable of the accurate LVEF measurement when the acquired views are of at least good imaging quality.
Copyright © 2020 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Automated echocardiographic assessment; Handheld ultrasound devices; Left ventricular ejection fraction

Year:  2021        PMID: 33451814     DOI: 10.1016/j.ultrasmedbio.2020.12.003

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Machine learning algorithm using publicly available echo database for simplified "visual estimation" of left ventricular ejection fraction.

Authors:  Michael Blaivas; Laura Blaivas
Journal:  World J Exp Med       Date:  2022-03-20

2.  The quality, safety, feasibility, and interpretive accuracy of echocardiographic and lung ultrasound assessment of COVID-19 patients using a hand-held ultrasound.

Authors:  Ziv Dadon; Nir Levi; Evan Avraham Alpert; Amir Orlev; Daniel Belman; Michael Glikson; Adi Butnaru; Shmuel Gottlieb
Journal:  Echocardiography       Date:  2022-06-06       Impact factor: 1.874

3.  Real-time automatic quantification of left ventricular function by hand-held ultrasound devices in patients with suspected heart failure: a feasibility study of a diagnostic test with data from general practitioners, nurses and cardiologists.

Authors:  Anna Katarina Hjorth-Hansen; Malgorzata Izabela Magelssen; Garrett Newton Andersen; Torbjørn Graven; Jens Olaf Kleinau; Bodil Landstad; Lasse Løvstakken; Kyrre Skjetne; Ole Christian Mjølstad; Havard Dalen
Journal:  BMJ Open       Date:  2022-10-13       Impact factor: 3.006

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.