Literature DB >> 33450504

Risk assessment of resurfacing implant loosening and femur fracture under low-energy impacts taking into account degenerative changes in bone tissues. Computer simulation.

Galina M Eremina1, Alexey Yu Smolin2.   

Abstract

BACKGROUND AND
OBJECTIVE: Degenerative diseases of the musculoskeletal system significantly reduce the quality of human life. Hip resurfacing is used to treat degenerative diseases in the later stages. After surgery, there is a risk of endoprosthesis loosening and low-energy fracture during daily physical activity. Computer modeling is a promising way to predict the optimal low-energy loads that do not lead to bone destruction. This paper aims to study numerically the mechanical behavior of the proximal femur, amenable to degenerative changes and subjected to hip resurfacing under low-energy impact equivalent to physiological loads.
METHODS: A numerical model of the mechanical behavior of the femur after hip resurfacing arthroplasty under low-energy impacts equivalent to physiological loads is presented. The model is based on the movable cellular automaton method (discrete elements), where the mechanical behavior of bone tissue is described using the Biot poroelasticity accounting for the presence and transfer of interstitial biological fluid.
RESULTS: For the first time, it is shown that a poroelastic model allows predicting the service life of endoprostheses, taking into account the individual characteristics of the bone tissues amenable to various degenerative diseases. The obtained results indicate that the changes in the bone properties have a significant influence on the critical forces corresponding to the first appearance of microcracks and the fracture formation. At the same time, their effect on the type of fracture is negligible. A much more impact on the type of fracture has the kinematic and dynamic conditions of the exposure.
CONCLUSIONS: The obtained results show the promise of using the proposed model for predicting the operational resource of resurfacing endoprostheses, taking into account the physiological features of the structure of the patient's bone tissues.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bone diseases and mechanical properties; Computer simulation; Femur fracture; Hip resurfacing; Physiological loading; Poroelastic model

Mesh:

Year:  2021        PMID: 33450504     DOI: 10.1016/j.cmpb.2021.105929

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  2 in total

1.  Development of a Computational Model of the Mechanical Behavior of the L4-L5 Lumbar Spine: Application to Disc Degeneration.

Authors:  Galina Eremina; Alexey Smolin; Jing Xie; Vladimir Syrkashev
Journal:  Materials (Basel)       Date:  2022-09-26       Impact factor: 3.748

2.  Numerical Modeling of Shockwave Treatment of Knee Joint.

Authors:  Galina Eremina; Alexey Smolin
Journal:  Materials (Basel)       Date:  2021-12-13       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.