Literature DB >> 3344818

Matching between feline left ventricle and arterial load: optimal external power or efficiency.

G P Toorop1, G J Van den Horn, G Elzinga, N Westerhof.   

Abstract

We tested the hypothesis that the feline left ventricle normally works at optimal external power as opposed to optimal efficiency by (re)analyzing data from five isolated, blood-perfused cat hearts and 39 open-thorax cats. In the isolated hearts, we measured pump function, external steady power, myocardial oxygen consumption, and efficiency. Optimal external power and optimal efficiency were found at different left ventricular outputs (6.94 +/- 0.33 and 8.35 +/- 0.37 ml/s, respectively; P less than 0.001). In the in situ cat hearts the working point was found at an output of 4.72 +/- 0.32 ml/s, whereas optimal external power was found at 4.84 +/- 0.26 ml/s. These values were not significantly different. Assuming that the point of optimal efficiency was located at the same fraction of the maximal unloaded left ventricular output (Fmax) as in the isolated hearts, i.e., 0.7, we found the point of optimal efficiency for the in situ heart at a flow of 5.83 +/- 0.32 ml/s, which was significantly different (P less than 0.001) from the flow in the working point. Our data therefore indicate that the left ventricle in the open-thorax cat is matched to the arterial load such that its external power output rather than efficiency is optimized.

Entities:  

Mesh:

Year:  1988        PMID: 3344818     DOI: 10.1152/ajpheart.1988.254.2.H279

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  10 in total

1.  Importance of mitral subvalvular apparatus in terms of cardiac energetics and systolic mechanics in the ejecting canine heart.

Authors:  K L Yun; M A Niczyporuk; G E Sarris; J I Fann; D C Miller
Journal:  J Clin Invest       Date:  1991-01       Impact factor: 14.808

2.  Interventricular comparison of the energetics of contraction of trabeculae carneae isolated from the rat heart.

Authors:  June-Chiew Han; Andrew J Taberner; Poul M F Nielsen; Denis S Loiselle
Journal:  J Physiol       Date:  2012-11-26       Impact factor: 5.182

3.  Cardiodynamic conditions for the linearity of preload recruitable stroke work.

Authors:  H Takaoka; H Suga; Y Goto; K Hata; M Takeuchi
Journal:  Heart Vessels       Date:  1995       Impact factor: 2.037

Review 4.  Age-related changes in venticular-arterial coupling: pathophysiologic implications.

Authors:  David A Kass
Journal:  Heart Fail Rev       Date:  2002-01       Impact factor: 4.214

Review 5.  The velocity of cardiac sarcomere shortening: mechanisms and implications.

Authors:  Pieter P de Tombe; Henk E D J ter Keurs
Journal:  J Muscle Res Cell Motil       Date:  2012-06-30       Impact factor: 2.698

6.  Relationship between capillaries, mitochondria and maximum power of the heart: a meta-study from shrew to elephant.

Authors:  Heidi D Horrell; Anika Lindeque; Anthony P Farrell; Roger S Seymour; Craig R White; Kayla M Kruger; Edward P Snelling
Journal:  Proc Biol Sci       Date:  2022-02-09       Impact factor: 5.349

7.  Coupling of the left ventricular and arterial system.

Authors:  W C Little; C P Cheng
Journal:  Med Biol Eng Comput       Date:  1994-03       Impact factor: 2.602

Review 8.  Cardiac efficiency.

Authors:  J D Schipke
Journal:  Basic Res Cardiol       Date:  1994 May-Jun       Impact factor: 17.165

9.  The afterload-dependent peak efficiency of the isolated working rat heart is unaffected by streptozotocin-induced diabetes.

Authors:  June-Chiew Han; Soyeon Goo; Carolyn J Barrett; Kimberley M Mellor; Andrew J Taberner; Denis S Loiselle
Journal:  Cardiovasc Diabetol       Date:  2014-01-05       Impact factor: 9.951

10.  A computationally efficient physiologically comprehensive 3D-0D closed-loop model of the heart and circulation.

Authors:  Christoph M Augustin; Matthias A F Gsell; Elias Karabelas; Erik Willemen; Frits W Prinzen; Joost Lumens; Edward J Vigmond; Gernot Plank
Journal:  Comput Methods Appl Mech Eng       Date:  2021-08-18       Impact factor: 6.756

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.