Literature DB >> 33446225

Impact of four-dimensional cone-beam computed tomography on target localization for gastric mucosa-associated lymphoid tissue lymphoma radiotherapy: reducing planning target volume.

Yoshinobu Shimohigashi1, Ryo Toya2, Tetsuo Saito2, Yumiko Kono3, Yasuhiro Doi3, Yoshiyuki Fukugawa2, Takahiro Watakabe2, Tadashi Matsumoto2, Yudai Kai3, Masato Maruyama3, Natsuo Oya2.   

Abstract

BACKGROUND: Radiotherapy of gastric mucosa-associated lymphoid tissue (MALT) lymphoma should be delivered to the entire stomach with planning target volume (PTV) that accounts for variations in stomach volume, respiratory movement, and patient set-up error. In this study, we evaluated whether the use of four-dimensional cone-beam computed tomography (4D-CBCT) reduces the PTV.
METHODS: Eight patients underwent radiotherapy with 15 fractions of gastric MALT lymphoma using 4D-CBCT. PTV structures of 5-30 mm margins (5 mm intervals) from the clinical target volume (CTV) delineated based on the 4D-CT images (CTV-4D) were generated. For the target localization, we performed matching based on skin marking (skin matching), bone anatomy (bone matching), and stomach anatomy (4D soft-tissue matching) based on registration between planning CT and 4D-CBCT images from 10 phases. For each patient, we calculated the covering ratio (CR) of the stomach with variable PTV structures, based on the 4D-CBCT images, with a total of 150 phases [CR (%) = (number of covering phases/150 phases) × 100], for three target localization methods. We compared the CR values of the different target localization methods and defined the PTV with an average CR of ≥ 95% for all patients.
RESULTS: The average CR for all patients increased from 17.9 to 100%, 19.6 to 99.8%, and 33.8 to 100%, in the skin, bone, and 4D soft-tissue matchings, respectively, as the PTV structures increased from 5 to 30 mm. The CR obtained by 4D soft-tissue matching was superior to that obtained by skin (P = 0.013) and bone matching (P = 0.008) for a PTV structure of 15 mm margin. The PTV required an additional margin of 20 mm (average CR: 95.2%), 25 mm (average CR: 99.1%), and 15 mm (average CR: 98.0%) to CTV-4D for the skin, bone, and 4D soft-tissue matchings, respectively.
CONCLUSIONS: This study demonstrates that the use of 4D-CBCT reduces the PTV when applying 4D soft-tissue matching, compared to skin and bone matchings. Additionally, bone matching does not reduce the PTV as compared with traditional skin matching.

Entities:  

Keywords:  Four-dimensional computed tomography; Four-dimensional cone-beam computed tomography; Image-guided radiotherapy; Malignant lymphoma; Mucosa-associated lymphoid tissue lymphoma; Planning target volume

Year:  2021        PMID: 33446225     DOI: 10.1186/s13014-020-01734-w

Source DB:  PubMed          Journal:  Radiat Oncol        ISSN: 1748-717X            Impact factor:   3.481


  1 in total

1.  Dose-function Histogram Evaluation Using 99mTc-GSA SPECT/CT Images for Stereotactic Body Radiation Therapy Planning for Hepatocellular Carcinoma Patients: A Dosimetric Parameter Comparison.

Authors:  Ryo Toya; Tetsuo Saito; Shinya Shiraishi; Yudai Kai; Ryuji Murakami; Tomohiko Matsuyama; Takahiro Watakabe; Fumi Sakamoto; Noriko Tsuda; Yoshinobu Shimohigashi; Yasuyuki Yamashita; Natsuo Oya
Journal:  Anticancer Res       Date:  2018-03       Impact factor: 2.480

  1 in total
  1 in total

1.  Implementation of 99mTc-GSA SPECT Image-guided Inverse Planning into Palliative Radiotherapy for Diffuse Liver Metastases: A Novel Approach.

Authors:  Ryo Toya; Takahiro Watakabe; Yudai Kai; Tomohiko Matsuyama; Yoshiyuki Fukugawa; Tadashi Matsumoto; Shinya Shiraishi; Yoshinobu Shimohigashi; Sho Saeki; Takuro Sakagami; Toshinori Hirai; Natsuo Oya
Journal:  In Vivo       Date:  2022 May-Jun       Impact factor: 2.406

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.