Literature DB >> 33445723

Towards Automated Eye Diagnosis: An Improved Retinal Vessel Segmentation Framework Using Ensemble Block Matching 3D Filter.

Khuram Naveed1, Faizan Abdullah2, Hussain Ahmad Madni1, Mohammad A U Khan3, Tariq M Khan2, Syed Saud Naqvi1.   

Abstract

Automated detection of vision threatening eye disease based on high resolution retinal fundus images requires accurate segmentation of the blood vessels. In this regard, detection and segmentation of finer vessels, which are obscured by a considerable degree of noise and poor illumination, is particularly challenging. These noises include (systematic) additive noise and multiplicative (speckle) noise, which arise due to various practical limitations of the fundus imaging systems. To address this inherent issue, we present an efficient unsupervised vessel segmentation strategy as a step towards accurate classification of eye diseases from the noisy fundus images. To that end, an ensemble block matching 3D (BM3D) speckle filter is proposed for removal of unwanted noise leading to improved detection. The BM3D-speckle filter, despite its ability to recover finer details (i.e., vessels in fundus images), yields a pattern of checkerboard artifacts in the aftermath of multiplicative (speckle) noise removal. These artifacts are generally ignored in the case of satellite images; however, in the case of fundus images, these artifacts have a degenerating effect on the segmentation or detection of fine vessels. To counter that, an ensemble of BM3D-speckle filter is proposed to suppress these artifacts while further sharpening the recovered vessels. This is subsequently used to devise an improved unsupervised segmentation strategy that can detect fine vessels even in the presence of dominant noise and yields an overall much improved accuracy. Testing was carried out on three publicly available databases namely Structured Analysis of the Retina (STARE), Digital Retinal Images for Vessel Extraction (DRIVE) and CHASE_DB1. We have achieved a sensitivity of 82.88, 81.41 and 82.03 on DRIVE, SATARE, and CHASE_DB1, respectively. The accuracy is also boosted to 95.41, 95.70 and 95.61 on DRIVE, SATARE, and CHASE_DB1, respectively. The performance of the proposed methods on images with pathologies was observed to be more convincing than the performance of similar state-of-the-art methods.

Entities:  

Keywords:  Block Matching 3D (BM3D); Diabetic Retinopathy (DR); Vascular Endothelial Growth Factor (VEGF); retina; speckle noise

Year:  2021        PMID: 33445723      PMCID: PMC7828181          DOI: 10.3390/diagnostics11010114

Source DB:  PubMed          Journal:  Diagnostics (Basel)        ISSN: 2075-4418


  42 in total

1.  Image denoising with 2D scale-mixing complex wavelet transforms.

Authors:  Norbert Remenyi; Orietta Nicolis; Guy Nason; Brani Vidakovic
Journal:  IEEE Trans Image Process       Date:  2014-10-08       Impact factor: 10.856

2.  The SURE-LET approach to image denoising.

Authors:  Thierry Blu; Florian Luisier
Journal:  IEEE Trans Image Process       Date:  2007-11       Impact factor: 10.856

3.  Iterative weighted maximum likelihood denoising with probabilistic patch-based weights.

Authors:  Charles-Alban Deledalle; Loïc Denis; Florence Tupin
Journal:  IEEE Trans Image Process       Date:  2009-08-07       Impact factor: 10.856

4.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

5.  Locating blood vessels in retinal images by piece-wise threshold probing of a matched filter response.

Authors:  A Hoover; V Kouznetsova; M Goldbaum
Journal:  Proc AMIA Symp       Date:  1998

6.  Retinal vessel extraction by matched filter with first-order derivative of Gaussian.

Authors:  Bob Zhang; Lin Zhang; Lei Zhang; Fakhri Karray
Journal:  Comput Biol Med       Date:  2010-03-03       Impact factor: 4.589

7.  A Skeletal Similarity Metric for Quality Evaluation of Retinal Vessel Segmentation.

Authors:  Zengqiang Yan; Xin Yang; Kwang-Ting Cheng
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

8.  The number of people with glaucoma worldwide in 2010 and 2020.

Authors:  H A Quigley; A T Broman
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

9.  A robust technique based on VLM and Frangi filter for retinal vessel extraction and denoising.

Authors:  Khan Bahadar Khan; Amir A Khaliq; Abdul Jalil; Muhammad Shahid
Journal:  PLoS One       Date:  2018-02-12       Impact factor: 3.240

10.  Retinal Blood Velocity and Flow in Early Diabetes and Diabetic Retinopathy Using Adaptive Optics Scanning Laser Ophthalmoscopy.

Authors:  Cherilyn Mae A Palochak; Hee Eun Lee; Jessica Song; Andrew Geng; Robert A Linsenmeier; Stephen A Burns; Amani A Fawzi
Journal:  J Clin Med       Date:  2019-08-03       Impact factor: 4.241

View more
  2 in total

1.  DAVS-NET: Dense Aggregation Vessel Segmentation Network for retinal vasculature detection in fundus images.

Authors:  Mohsin Raza; Khuram Naveed; Awais Akram; Nema Salem; Amir Afaq; Hussain Ahmad Madni; Mohammad A U Khan; Mui-Zzud- Din
Journal:  PLoS One       Date:  2021-12-31       Impact factor: 3.240

2.  Diabetic and Hypertensive Retinopathy Screening in Fundus Images Using Artificially Intelligent Shallow Architectures.

Authors:  Muhammad Arsalan; Adnan Haider; Jiho Choi; Kang Ryoung Park
Journal:  J Pers Med       Date:  2021-12-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.