Literature DB >> 33444405

The effects of laser displacement on femtosecond laser-assisted conjunctival autograft preparation for pterygium surgery.

Valencia Hui Xian Foo1,2, Yu-Chi Liu1,2,3, Hon Shing Ong1,2,3, Marcus Ang1,2,3, Jodhbir S Mehta1,2,3.   

Abstract

AIMS: To evaluate the effects of no-suction femtosecond laser (FSL) stability on conjunctival autograft (CAG) dissection in pterygium surgery.
METHODS: Prospective analysis of 35 eyes from 34 subjects who underwent femtosecond laser-assisted pterygium surgery with the Ziemer Z8 laser (Ophthalmic Systems AG, Switzerland). Intraoperative absolute FSL displacements were measured and correlated with the duration and ease of CAG peel, CAG thickness, measured with intraoperative optical coherence tomography, and deviation from intended graft thickness.
RESULTS: The median absolute FSL displacement was 22 μm (interquartile range [IQR] 14.7 to 60.8), while median vertical FSL displacement was 14.7 μm (IQR 7.3 to 44) and median horizontal FSL displacement was 22.0 μm (IQR 14.7 to 44). 65.7% had a grade 1 peel, 11.4% had grade 2 peel, 14.3% had grade 3 peel and 8.6% had grade 4 peel. The median duration of CAG peel was 5.4 seconds (IQR 3 to 21.4). The median CAG thickness was 69 μm (IQR 60.3 to 78.5), and the median deviation from targeted graft thickness was 9 μm (IQR 1 to 16). Eyes with more difficult peels and longer duration of CAG peels had significantly greater vertical FSL displacements (p = 0.04 and 0.02 respectively), but not horizontal displacement, age, ethnicity, CAG thickness or deviation from original thickness, compared to those with better quality and shorter duration peels. 1 eye (2.9%) had an incomplete CAG peel with a buttonhole and 2 eyes had graft tears (5.7%).
CONCLUSION: Micro-displacements during the suction-free CAG preparation are common but they did not affect the quality of the CAG peel, duration of peel, or CAG thickness. However, vertical globe displacement during FSL-assisted CAG creation was significantly associated with a more difficult and longer CAG peel duration. This highlights the importance of the cornea traction suture fixation to ensure stability of the eye during FSL application.

Entities:  

Year:  2021        PMID: 33444405      PMCID: PMC7808670          DOI: 10.1371/journal.pone.0245223

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


  24 in total

1.  Analysis of variation in success rates in conjunctival autografting for primary and recurrent pterygium.

Authors:  S E Ti; S P Chee; K B Dear; D T Tan
Journal:  Br J Ophthalmol       Date:  2000-04       Impact factor: 4.638

2.  Bulbar conjunctival thickness measurements with optical coherence tomography in healthy chinese subjects.

Authors:  Xingru Zhang; Qingsong Li; Minhong Xiang; Haidong Zou; Bin Liu; Huanming Zhou; Zhumei Han; Zhixuan Fu; Zhenyong Zhang; Hanmin Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-07-12       Impact factor: 4.799

3.  Pterygium: a geographical study.

Authors:  R Detels; S P Dhir
Journal:  Arch Ophthalmol       Date:  1967-10

Review 4.  Treatment of pterygium.

Authors:  Isyaku Mohammed
Journal:  Ann Afr Med       Date:  2011 Jul-Sep

Review 5.  Femtosecond laser-assisted conjunctival autograft preparation for pterygium surgery.

Authors:  Matthias Fuest; Yu-Chi Liu; Gary Hin-Fai Yam; Ericia Pei Wen Teo; Hla Myint Htoon; Minas T Coroneo; Jodhbir S Mehta
Journal:  Ocul Surf       Date:  2016-12-03       Impact factor: 5.033

Review 6.  Femtosecond laser technology in corneal refractive surgery: a review.

Authors:  George D Kymionis; Vardhaman P Kankariya; Argyro D Plaka; Dan Z Reinstein
Journal:  J Refract Surg       Date:  2012-12       Impact factor: 3.573

Review 7.  Conjunctival autograft for pterygium.

Authors:  Elizabeth Clearfield; Valliammai Muthappan; Xue Wang; Irene C Kuo
Journal:  Cochrane Database Syst Rev       Date:  2016-02-11

Review 8.  Enhanced trabeculectomy: the Moorfields Safer Surgery System.

Authors:  Peng Tee Khaw; Mark Chiang; Peter Shah; Freda Sii; Alastair Lockwood; Ashkan Khalili
Journal:  Dev Ophthalmol       Date:  2012-04-17

9.  Comparison of intra-ocular pressure changes with liquid or flat applanation interfaces in a femtosecond laser platform.

Authors:  G P Williams; H P Ang; B L George; Y C Liu; G Peh; L Izquierdo; D T Tan; J S Mehta
Journal:  Sci Rep       Date:  2015-10-06       Impact factor: 4.379

10.  Cataract Surgery Performed by High Frequency LDV Z8 Femtosecond Laser: Safety, Efficacy, and Its Physical Properties.

Authors:  Bojan Pajic; Zeljka Cvejic; Brigitte Pajic-Eggspuehler
Journal:  Sensors (Basel)       Date:  2017-06-18       Impact factor: 3.576

View more