Literature DB >> 33432990

Visual and Refractive Outcomes With the Eyecryl Phakic Toric IOL Versus the Visian Toric Implantable Collamer Lens: Results of a 2-Year Prospective Comparative Study.

Sheetal Brar, Megha Gautam, Smith Snehal Sute, Savio Pereira, Sri Ganesh.   

Abstract

PURPOSE: To compare the 2-year visual and refractive outcomes with the Eyecryl Phakic Toric IOL (EP TIOL) (Biotech Vision Care Pvt Ltd) and Visian Toric ICL (TICL) (STAAR Surgical) for correction of high myopic astigmatism.
METHODS: This prospective, interventional, non-randomized comparison study included eligible patients who underwent toric phakic IOL surgery in one or both eyes with either the EP TIOL or TICL for myopic astigmatism. Two years postoperatively, both lenses were compared for their safety, efficacy, stability, and patient satisfaction. Vector analysis of astigmatism was performed using the Alpins method with the ASSORT software (ASSORT Party Ltd).
RESULTS: A total of 50 eyes were included, of which 25 eyes received EP TIOL implantation and the remaining 25 received TICL implantation. Preoperative mean ± standard deviation of spherical equivalent (SE) and cylinder was -10.15 ± 4.04 and -2.08 ± 0.86 diopters (D) in the EP TIOL group and -10.21 ± 3.97 and -2.17 ± 0.95 D in the TICL group, respectively. At 2 years of follow-up, there was no significant difference between the mean uncorrected distance visual acuity, corrected distance visual acuity, spherical equivalent, and residual astigmatism between the two groups (P > .05 for all parameters). Ninety-two percent of eyes in the EP TIOL group and 88% of eyes in the TICL group were within ±0.50 D of refractive astigmatism. Vector analysis of astigmatism showed a comparable Correction Index of 0.98 in the EP TIOL group and 0.94 in the TICL group, signifying a mild undercorrection of 2% and 6%, respectively. Two eyes in the TICL group underwent exchange for high vault and one eye required realignment due to significant postoperative rotation.
CONCLUSIONS: At least for the first 2 years postoperatively, both toric phakic IOLs were safe and effective in managing high myopic astigmatism with comparable visual results and patient satisfaction. [J Refract Surg. 2021;37(1):7-15.]. Copyright 2021, SLACK Incorporated.

Entities:  

Year:  2021        PMID: 33432990     DOI: 10.3928/1081597X-20201013-04

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Outcomes of the EVO ICL Using a Customized Non-horizontal or Horizontal Implanting Orientation Based on UBM Measurement: A Pilot Study.

Authors:  Ruoyan Wei; Mingrui Cheng; Lingling Niu; Lin Wang; Xiumei Luo; Meiyan Li; Xiaodong Zhou; Xiaoying Wang; Xingtao Zhou; Peijun Yao
Journal:  Ophthalmol Ther       Date:  2022-04-12

2.  Factors leading to realignment or exchange after implantable collamer lens implantation in 10 258 eyes.

Authors:  Ruoyan Wei; Meiyan Li; Aruma Aruma; Michael C Knorz; Dong Yang; Yongfu Yu; Xiaoying Wang; Joanne Choi; Peijun Yao; Xingtao Zhou
Journal:  J Cataract Refract Surg       Date:  2022-03-30       Impact factor: 3.528

3.  Toric Implantable Collamer Lens for the Treatment of Myopic Astigmatism.

Authors:  Majid Moshirfar; Nour Bundogji; Alyson N Tukan; James H Ellis; Shannon E McCabe; Ayesha Patil; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Clin Ophthalmol       Date:  2021-07-06
  3 in total