Literature DB >> 3343263

Tears of the meniscus as revealed by magnetic resonance imaging.

I Silva1, D M Silver.   

Abstract

Forty-four patients who were examined by magnetic resonance imaging and arthroscopy to detect tears of the meniscus of the knee were studied. Twenty-eight patients (Group I) had had no previous operations on the knee. Sixteen patients (Group II) had had a previous operation on the knee that had been performed after a meniscal injury. In Group I, the percentage of correct diagnoses by magnetic resonance imaging was 45 per cent. If the false-negative results are excluded, the rate of accuracy was 65 per cent. Similarly poor results were found in Group II: a rate of accuracy of 49 per cent and, if we eliminate the false-negative results, the rate of accuracy was only 55 per cent.

Entities:  

Mesh:

Year:  1988        PMID: 3343263

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  11 in total

1.  Meniscal bucket handle tears: a retrospective study of arthroscopy and the relation to MRI.

Authors:  A N Ververidis; D A Verettas; K J Kazakos; C E Tilkeridis; C N Chatzipapas
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-09-15       Impact factor: 4.342

2.  The double ACL sign: an unusual bucket-handle tear of medial meniscus.

Authors:  Koji Takayama; Takehiko Matsushita; Tomoyuki Matsumoto; Seiji Kubo; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-02-19       Impact factor: 4.342

3.  Impact of MRI on a knee arthroscopy waiting list.

Authors:  R L Williams; L A Williams; R Watura; J A Fairclough
Journal:  Ann R Coll Surg Engl       Date:  1996-09       Impact factor: 1.891

Review 4.  Histological scoring systems for tissue-engineered, ex vivo and degenerative meniscus.

Authors:  Umile Giuseppe Longo; Mattia Loppini; Giovanni Romeo; Nicola Maffulli; Vincenzo Denaro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-26       Impact factor: 4.342

5.  Comparison of low-field (0.2 Tesla) and high-field (1.5 Tesla) magnetic resonance imaging of the knee joint.

Authors:  B Kladny; K Glückert; B Swoboda; W Beyer; G Weseloh
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

6.  Closing the audit circle: effect of continuing audit on arthroscopic practice.

Authors:  N C Birch; D P Powles; J H Dorrell
Journal:  Ann R Coll Surg Engl       Date:  1993-11       Impact factor: 1.891

7.  Value of the coronal plane in MRI of internal derangement of the knee.

Authors:  N Haramati; R B Staron; S Cushin; E L Nickoloff; F Feldman
Journal:  Skeletal Radiol       Date:  1994-04       Impact factor: 2.199

8.  MRI of the knee joint with a 3-D gradient echo sequence. Equivalent to diagnostic arthroscopy?

Authors:  K Glückert; B Kladny; A Blank-Schäl; G Hofmann
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

9.  Accuracy of clinical diagnosis in knee arthroscopy.

Authors:  Stuart Brooks; Mamdouh Morgan
Journal:  Ann R Coll Surg Engl       Date:  2002-07       Impact factor: 1.891

10.  Free medial meniscal fragment which mimics the dislocated bucket-handle tear on MRI.

Authors:  Faik Türkmen; Ismail Hakkı Korucu; Cem Sever; Mehmet Demirayak; Gani Goncü; Serdar Toker
Journal:  Case Rep Orthop       Date:  2014-06-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.