Literature DB >> 33430847

A retrospective cohort study on prevalence of postoperative complications in comminuted patellar fractures: comparisons among stabilized with Cannulated-Screw, Kirschner-Wire, or Ring-Pin Tension Bands.

Xiao-Zhong Zhu1, Teng-Li Huang1, Hong-Yi Zhu1, Bing-Bo Bao1, Tao Gao1, Xing-Wei Li1, Jun-Qing Lin1, Xian-You Zheng2.   

Abstract

BACKGROUND: Displaced patellar fractures are commonly treated with open reduction and fixation with several different types of tension-band (TB) constructs. The main objective of this study was to compare the prevalence of postoperative complications after surgical stabilization of comminuted patellar fractures with either a modified Kirschner-wire tension band (MKTB), a cannulated-screw tension band (CSTB), or a ring-pin tension band (RPTB).
METHODS: We conducted a retrospective and consecutive cohort study of comminuted patellar fractures (n = 334) stabilized using a TB construct. Postoperative premature loss of reduction, infection, and skin breakdown were compared according to the type of TB constructs received (MKTB, CSTB, or RPTB). The rate of implant removal due to symptomatic hardware was also evaluated.
RESULTS: Fixation failure rate was significantly different among the groups (P = 0.013), with failure rates of 4.7% observed in the MKTB group,14.5% in the CSTB group, and 4.9% in the RPTB group. Skin breakdown and infection were not significantly different among the groups (Ps > 0.05). Due to symptomatic hardware, 40.5% of the patients in the MKTB group, 22.9% in the CSTB group, and 24.3% in the RPTB group underwent implant removal (P = 0.004). After adjusting for age, gender, comorbidities, number of supplementary screws/K-wires, and use of cerclage cables, multivariate regression analysis revealed that CSTB contributed to a 2.08-times greater risk of fixation failure compared to RPTB, while MKTB and RPTB were similar in risk of failure. In addition, it was found that patients who underwent MKTB fixation were more than twice as likely to undergo implant removal for symptomatic hardware compared with RPTB (odds ratio = 2.11, 95% CI = 1.20 to 3.72; P = 0.010).
CONCLUSIONS: RPTB have advantage over MKTB and CSTB fixation in terms of symptomatic hardware and premature failure, respectively. LEVEL OF EVIDENCE: Therapeutic Level III.

Entities:  

Keywords:  Kirschner‐wirecannulated‐screw; Patellar fractures; Ring‐pin; Tension band

Mesh:

Year:  2021        PMID: 33430847      PMCID: PMC7798242          DOI: 10.1186/s12891-020-03936-5

Source DB:  PubMed          Journal:  BMC Musculoskelet Disord        ISSN: 1471-2474            Impact factor:   2.362


  28 in total

1.  Multiplanar Fixation for Patella Fractures Using a Low-Profile Mesh Plate.

Authors:  Dean G Lorich; Stephen J Warner; Patrick C Schottel; Andre D Shaffer; Lionel E Lazaro; David L Helfet
Journal:  J Orthop Trauma       Date:  2015-12       Impact factor: 2.512

2.  Plating of patella fractures: techniques and outcomes.

Authors:  Benjamin C Taylor; Sanjay Mehta; Joaquin Castaneda; Bruce G French; Chris Blanchard
Journal:  J Orthop Trauma       Date:  2014-09       Impact factor: 2.512

3.  Locked tension band wiring using ring pins for patellar fractures: a method of minimising implant migration.

Authors:  Min Bom Kim; Young Ho Lee; Woo Cheol Shin; Goo Hyun Baek
Journal:  Arch Orthop Trauma Surg       Date:  2014-08-13       Impact factor: 3.067

4.  Patellar tension band wiring: a revised technique.

Authors:  C C Wu; C L Tai; W J Chen
Journal:  Arch Orthop Trauma Surg       Date:  2001       Impact factor: 3.067

5.  Patellar Fractures: Contemporary Approach to Treatment.

Authors: 
Journal:  J Am Acad Orthop Surg       Date:  1997-11       Impact factor: 3.020

Review 6.  Patellar fractures in adults.

Authors:  J Stuart Melvin; Samir Mehta
Journal:  J Am Acad Orthop Surg       Date:  2011-04       Impact factor: 3.020

7.  Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database and outcomes committee.

Authors:  J L Marsh; Theddy F Slongo; Julie Agel; J Scott Broderick; William Creevey; Thomas A DeCoster; Laura Prokuski; Michael S Sirkin; Bruce Ziran; Brad Henley; Laurent Audigé
Journal:  J Orthop Trauma       Date:  2007 Nov-Dec       Impact factor: 2.512

8.  Fracture of the patella. A study of 422 patellar fractures.

Authors:  A Boström
Journal:  Acta Orthop Scand Suppl       Date:  1972

9.  Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires.

Authors:  C Max Hoshino; Wesley Tran; John V Tiberi; Mary Helen Black; Bonnie H Li; Stuart M Gold; Ronald A Navarro
Journal:  J Bone Joint Surg Am       Date:  2013-04-03       Impact factor: 5.284

10.  Cannulated screw and cable are superior to modified tension band in the treatment of transverse patella fractures.

Authors:  Yun Tian; Fang Zhou; Hongquan Ji; Zhishan Zhang; Yan Guo
Journal:  Clin Orthop Relat Res       Date:  2011-05-15       Impact factor: 4.176

View more
  3 in total

1.  Clinical Outcomes of Cannulated Screws versus Ring Pin versus K-Wire with Tension Band Fixation Techniques in the Treatment of Transverse Patellar Fractures: A Case-Control Study with Minimum 2-Year Follow-Up.

Authors:  Junchuan Liu; Yiming Ge; Guolei Zhang; Xuehong Zheng; Liang Gao; Enzeng Xing; Jiangfeng Lu; Jun Di; Junfei Guo
Journal:  Biomed Res Int       Date:  2022-06-15       Impact factor: 3.246

2.  Multi-planar fixation of displaced, multi-fragmentary patella fractures in elderly patients with anterior locking plates and cerclage wires: preliminary results.

Authors:  Xuetao Xie; Yi Zhu; Yukai Wang; Yu Zhan; Saura-Sanchez Eladio; Congfeng Luo
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-10-23

3.  Incidence of Implant Removal in Surgically Treated Patella Fractures.

Authors:  Shivanshu Mittal; Vivek K David; Vikas Sharma
Journal:  Cureus       Date:  2022-05-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.