Literature DB >> 33430821

A comparison of optic disc area measured by confocal scanning laser tomography versus Bruch's membrane opening area measured using optical coherence tomography.

Ioana Maria Cazana1, Daniel Böhringer2, Thomas Reinhard2, Charlotte Evers2, Diana Engesser2, Alexandra Anton2, Jan Lübke2.   

Abstract

BACKGROUND: Precise optic disc size measurements based on anatomically exact disc margins are fundamental for a correct assessment of glaucoma suspects. Computerized imaging techniques, such as confocal-scanning-laser-tomography (CSLT), which applies operator defined boundaries and optical-coherence-tomography (OCT), which incorporates an alternative detectable landmark (Bruch's-membrane-opening (BMO)), have simplified the planimetry of the optic disc and BMO-area, respectively. This study's objectives are to compare both modalities for area and to define a threshold for macro-BMO using BMO-OCT.
METHODS: Retrospectively, patients that simultaneously received CSLT and BMO-OCT scans were included. Their images were correlated and agreement was determined using Bland-Altman-analysis. The diagnostic power of a macro-BMO threshold using OCT was derived after creating a receiver-operating-characteristics-curve using the well-established analogous CSLT threshold (2.43 mm2).
RESULTS: Our study included 373 eyes with a median optic disc area by CSLT/ BMO-area by OCT of 2.56 mm2 and 2.19 mm2 respectively. The Bland-Altman-analysis revealed a systematic deviation with a diverging tendency with increasing area, which enabled the creation of the following mathematical relation: disc-area (CSLT)*0.73 + 0.3 = BMO-area (OCT). BMO-area of 2.19 mm2 showed the best diagnostic power for identifying macro-BMOs using OCT (sensitivity: 75%, specificity: 86%).
CONCLUSIONS: Area measurements (CSLT optic disc area vs. BMO-area by OCT) showed a systematic deviation with a divergent tendency with increasing size. Our mathematical equation offers an estimated comparison of these anatomically diverse entities. Considering BMO-OCT´ anatomical accuracy, the 2.19 mm2 threshold may improve discernment between glaucoma suspects and norm variants.

Entities:  

Keywords:  BMO-OCT; CSLT; Glaucoma; Macrodiscs

Mesh:

Year:  2021        PMID: 33430821      PMCID: PMC7802149          DOI: 10.1186/s12886-020-01799-x

Source DB:  PubMed          Journal:  BMC Ophthalmol        ISSN: 1471-2415            Impact factor:   2.209


  23 in total

Review 1.  Primary open-angle glaucoma.

Authors:  Robert N Weinreb; Peng Tee Khaw
Journal:  Lancet       Date:  2004-05-22       Impact factor: 79.321

2.  Optic disc measurements in myopia with optical coherence tomography and confocal scanning laser ophthalmoscopy.

Authors:  Christopher Kai-Shun Leung; Arthur Chak Kwan Cheng; Kelvin Kam Lung Chong; King Sai Leung; Shaheeda Mohamed; Charles Sing Lok Lau; Carol Yim Lui Cheung; Geoffrey Chin-Hung Chu; Ricky Yiu Kwong Lai; Calvin Chi Pui Pang; Dennis Shun Chiu Lam
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-07       Impact factor: 4.799

3.  Comparison of clinical and three-dimensional histomorphometric optic disc margin anatomy.

Authors:  Nicholas G Strouthidis; Hongli Yang; J Crawford Downs; Claude F Burgoyne
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-01-10       Impact factor: 4.799

4.  [Bruch's Membrane Opening in OCT in Correlation with Corneal Correction - a Pilot Study].

Authors:  J Luebke; D Böhringer; T Reinhard; A Anton
Journal:  Klin Monbl Augenheilkd       Date:  2016-08-01       Impact factor: 0.700

5.  Optic disc parameters and onset of glaucomatous field loss. I. Methods and progressive changes in disc morphology.

Authors:  A Sommer; I Pollack; A E Maumenee
Journal:  Arch Ophthalmol       Date:  1979-08

6.  Clinical histologic correlation of human peripapillary anatomy.

Authors:  F E Fantes; D R Anderson
Journal:  Ophthalmology       Date:  1989-01       Impact factor: 12.079

7.  Measurement of optic nerve head parameters: comparison of optical coherence tomography with digital planimetry.

Authors:  Chameen Samarawickrama; Amy Pai; Son C Huynh; George Burlutsky; Jost B Jonas; Paul Mitchell
Journal:  J Glaucoma       Date:  2009 Oct-Nov       Impact factor: 2.503

8.  Bruch's membrane opening-based optical coherence tomography of the optic nerve head: a useful diagnostic tool to detect glaucoma in macrodiscs.

Authors:  P Enders; F Schaub; W Adler; M M Hermann; T S Dietlein; C Cursiefen; L M Heindl
Journal:  Eye (Lond)       Date:  2018-01-26       Impact factor: 3.775

Review 9.  Heidelberg Retina Tomography analysis in optic disks with anatomic particularities.

Authors:  A M Dascalu; C Alexandrescu; R Pascu; R Ilinca; V Popescu; R Ciuluvica; L Voinea; C Celea
Journal:  J Med Life       Date:  2010 Oct-Dec

10.  The impact of optic nerve and related characteristics on disc area measurements derived from different imaging techniques.

Authors:  Michael Yapp; George Rennie; Michael P Hennessy; Michael Kalloniatis; Barbara Zangerl
Journal:  PLoS One       Date:  2018-01-17       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.