Hisao Shimizu1, Yoji Kuze1, Tomoaki Higuchi1, Shin-Ichi Matsumoto1, Syunsuke Yamamoto1, Akihiko Goto1, Yuu Moriya1, Hideki Hirabayashi1.
Abstract
INTRODUCTION: In the development of cell therapy products for human use, studies on the biodistribution of transplanted cells in animals are important for assessing the safety and efficacy of these products. Although a few reports have described the biodistribution of human cells in animals using Arthrobacter luteus-based-polymerase chain reaction (Alu-PCR), most have used genomic DNA or synthetic oligonucleotide as calibrators, as opposed to actual cells. In addition, bioanalytical variability in the quantification of cells with respect to specificity, selectivity, accuracy, and precision, has not been evaluated. Accordingly, in this study, we validated the utility of this bioanalytical method for human T cells in mice to establish assay performance using cells as a calibrator.Entities:
Keywords: Arthrobacter luteus; Biodistribution; Cell therapy; Polymerase chain reaction; Quantification; Validation
Year: 2020 PMID: 33426226 PMCID: PMC7770409 DOI: 10.1016/j.reth.2020.10.003
Source DB: PubMed Journal: Regen Ther ISSN: 2352-3204 Impact factor: 3.419
Fig. 1Proposed procedures for human cell quantification using quantitative polymerase chain reaction (qPCR) for biodistribution studies.
Concentrations of human cells in human T cell-spiked samples of mouse blood and tissues (n = 1) in assay specificity assessment.
| Nominal concentration (cells/50 μL blood or 15 mg tissue) | Blank | LLOQ |
|---|---|---|
| 0 | 10 | |
| Blood | 1.48 | 10.2 |
| Liver | 1.95 | 11.3 |
| Heart | 0.828 | 10.9 |
| Kidney | 0.779 | 10.0 |
| Lung | 1.10 | 10.7 |
| Spleen | 0.913 | 11.4 |
LLOQ: lower limit of quantification.
Cells/7.5 mg tissue.
Concentrations of human cells in human T-cell spiked samples from six individual mouse blood samples in assay selectivity assessment.
| Nominal concentration (cells/50 μL blood) | Blank | LLOQ |
|---|---|---|
| 0 | 10 | |
| Animal no. 1 | 1.10 | 9.08 |
| Animal no. 2 | 1.70 | 12.2 |
| Animal no. 3 | 1.38 | 13.1 |
| Animal no. 4 | 1.20 | 11.8 |
| Animal no. 5 | 1.42 | 12.0 |
| Animal no. 6 | 1.38 | 11.9 |
| Mean (cells/50 μL blood) | 1.17 | 11.4 |
| Precision (%CV) | 17.8 | 11.9 |
| Accuracy (%) | – | 114.4 |
LLOQ: lower limit of quantification, CV: coefficient of variation.
Fig. 2(a) Amplification plot of human cell-spiked mouse blood (n = 3), and (b) calibration curves for human cell-spiked mouse blood, liver, and heart samples (n = 3 for each sample type) assayed using the developed Arthrobacter luteus (Alu)-based qPCR method.
Calibration curves for mouse blood, liver, and heart samples.
| Nominal concentrations | Blood | Liver | Heart | |||
|---|---|---|---|---|---|---|
| Back-calculated concentrations (cells/50 μL blood) | Accuracy (%) | Back-calculated concentrations (cells/15 mg tissue) | Accuracy (%) | Back-calculated concentrations (cells/15 mg tissue) | Accuracy (%) | |
| 100,000 | 99,300 | 99.3 | 113,000 | 113.0 | 104,000 | 104.0 |
| 10,000 | 11,000 | 110.0 | 9500 | 95.0 | 10,300 | 103.0 |
| 1000 | 884 | 88.4 | 867 | 86.7 | 914 | 91.4 |
| 100 | 103 | 103.0 | 95.9 | 95.9 | 94.5 | 94.5 |
| 10 | 10.2 | 102.0 | 11.3 | 113.0 | 10.9 | 109.0 |
| 0 | 1.48 | – | 1.95 | – | 0.828 | – |
| Slope | −3.52 | −3.43 | −3.49 | |||
| Y-Intercept | 32.5 | 32.4 | 31.6 | |||
| R2 | 0.999 | 0.998 | 0.999 | |||
| PCR efficiency (%) | 92.5 | 95.5 | 93.4 | |||
Assay precision and accuracy using mouse blood.
| Run | Nominal Concentration (cells/50 μL blood) | Blood | |||
|---|---|---|---|---|---|
| LLOQ | Low | Medium | High | ||
| 10 | 30 | 1000 | 80,000 | ||
| 1 | Mean (cells/50 μL blood) | 11.1 | 28.5 | 992 | 66,400 |
| Precision (%CV) | 7.2 | 7.4 | 5.2 | 17.3 | |
| Accuracy (%) | 111.0 | 94.9 | 99.2 | 83.0 | |
| n | 5 | 5 | 5 | 5 | |
| 2 | Mean (cells/50 μL blood) | 9.45 | 24.5 | 861 | 70,600 |
| Precision (%CV) | 5.9 | 2.6 | 7.8 | 10.9 | |
| Accuracy (%) | 94.5 | 81.7 | 86.1 | 88.3 | |
| n | 5 | 5 | 5 | 5 | |
| 3 | Mean (cells/50 μL blood) | 8.43 | 23.0 | 744 | 59,600 |
| Precision (%CV) | 6.4 | 5.2 | 9.5 | 7.3 | |
| Accuracy (%) | 84.3 | 76.8 | 74.4 | 74.5 | |
| n | 5 | 5 | 5 | 5 | |
| Inter-assay | Mean (cells/50 μL blood) | 9.66 | 25.3 | 866 | 65,500 |
| Precision (%CV) | 13.3 | 10.7 | 13.9 | 13.8 | |
| Accuracy (%) | 96.6 | 84.4 | 86.6 | 81.9 | |
| n | 15 | 15 | 15 | 15 | |
Fig. 3Tissue and blood concentrations of human CD8+ T cells after a single intravenous administration to mice at (a) 1 h and (b) 24 h. Bars represents means ± standard deviations (SDs, n = 3). Percentage dose (1 × 106 cells/animal) for each tissue is indicated (n.c. = not calculated).