Literature DB >> 3342560

An evaluation of the mechanical failure modalities of a rotating hinge knee prosthesis.

M A Kester1, S D Cook, A F Harding, R P Rodriguez, C S Pipkin.   

Abstract

The clinical and metallurgical performance of 12 retrieved Noiles total knee prostheses was investigated. Clinical histories and serial roentgenograms were used in conjunction with the American Society for Testing and Materials (ASTM) standard implant retrieval and analysis techniques to assess device performance. All of the devices were removed because of implant loosening with pain, while two devices also had a late infection. The average time in situ for all devices was four years. Roentgenographically, all of the devices showed signs of progressive radiolucencies. Ten (83%) of the devices migrated proximally within the femur. A marked varus drift was observed in eight (67%) of the retrieved prostheses. Hypertrophy of the femoral cortex was observed in eight (67%) of the cases. Seventy-three percent of the polyethylene tibial stems exhibited extensive wear on the anterior and medial aspects of the articulating surface. Extensive wear was also seen on the anterior and extreme posterior aspects in 92% of the polyethylene tibial plateau bearings. This wear was a consequence of the migration of the femoral component leading to buttressing of the plastic components against bone or bone cement. This study indicates serious design flaws in the Noiles knee prosthesis that unless corrected would question the use of the device in either primary or revision knee surgery.

Entities:  

Mesh:

Year:  1988        PMID: 3342560

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

1.  Hinged total knee arthroplasty in the presence of ligamentous deficiency.

Authors:  Daniel Hernández-Vaquero; Manuel A Sandoval-García
Journal:  Clin Orthop Relat Res       Date:  2010-05       Impact factor: 4.176

2.  Revision knee arthroplasty with a rotating-hinge design in elderly patients with instability following total knee arthroplasty.

Authors:  E Carlos Rodríguez-Merchán; Primitivo Gómez-Cardero; Ángel Martínez-Lloreda
Journal:  J Clin Orthop Trauma       Date:  2014-11-20

3.  Long Term Results of a Rotating Hinge Total Knee Prosthesis With Carbon-Fiber Reinforced Poly-Ether-Ether-Ketone (CFR-PEEK) as Bearing Material.

Authors:  Klemens Vertesich; Kevin Staats; Christoph Böhler; Richard Koza; Richard Lass; Alexander Giurea
Journal:  Front Bioeng Biotechnol       Date:  2022-03-04

4.  Midterm Results of a New Rotating Hinge Knee Implant: A 5-Year Follow-Up.

Authors:  Christoph Böhler; Paul Kolbitsch; Reinhard Schuh; Richard Lass; Bernd Kubista; Alexander Giurea
Journal:  Biomed Res Int       Date:  2017-12-10       Impact factor: 3.411

Review 5.  Total knee arthroplasty using hinge joints: Indications and results.

Authors:  E Carlos Rodríguez-Merchán
Journal:  EFORT Open Rev       Date:  2019-04-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.