Ayushe A Sharma1,2,3, Rodolphe Nenert3,4, Christina Mueller1, Andrew A Maudsley5, Jarred W Younger1, Jerzy P Szaflarski2,3,4,6. 1. Department of Psychology, University of Alabama at Birmingham (UAB), Birmingham, AL, United States. 2. Department of Neurobiology, University of Alabama at Birmingham (UAB), Birmingham, AL, United States. 3. University of Alabama at Birmingham Epilepsy Center (UABEC), Birmingham, AL, United States. 4. Department of Neurology, University of Alabama at Birmingham (UAB), Birmingham, AL, United States. 5. Department of Radiology, Miller School of Medicine, University of Miami, Miami, FL, United States. 6. Department of Neurosurgery, University of Alabama at Birmingham (UAB), Birmingham, AL, United States.
Abstract
Background: Magnetic resonance spectroscopic imaging (MRSI) is a neuroimaging technique that may be useful for non-invasive mapping of brain temperature (i.e., thermometry) over a large brain volume. To date, intra-subject reproducibility of MRSI-based brain temperature (MRSI-t) has not been investigated. The objective of this repeated measures MRSI-t study was to establish intra-subject reproducibility and repeatability of brain temperature, as well as typical brain temperature range. Methods: Healthy participants aged 23-46 years (N = 18; 7 females) were scanned at two time points ~12-weeks apart. Volumetric MRSI data were processed by reconstructing metabolite and water images using parametric spectral analysis. Brain temperature was derived using the frequency difference between water and creatine (TCRE) for 47 regions of interest (ROIs) delineated by the modified Automated Anatomical Labeling (AAL) atlas. Reproducibility was measured using the coefficient of variation for repeated measures (COVrep), and repeatability was determined using the standard error of measurement (SEM). For each region, the upper and lower bounds of Minimal Detectable Change (MDC) were established to characterize the typical range of TCRE values. Results: The mean global brain temperature over all subjects was 37.2°C with spatial variations across ROIs. There was a significant main effect for time [F (1, 1,591) = 37.0, p < 0.0001] and for brain region [F (46, 1,591) = 2.66, p < 0.0001]. The time*brain region interaction was not significant [F (46, 1,591) = 0.80, p = 0.83]. Participants' TCRE was stable for each ROI across both time points, with ROIs' COVrep ranging from 0.81 to 3.08% (mean COVrep = 1.92%); majority of ROIs had a COVrep <2.0%. Conclusions: Brain temperature measurements were highly consistent between both time points, indicating high reproducibility and repeatability of MRSI-t. MRSI-t may be a promising diagnostic, prognostic, and therapeutic tool for non-invasively monitoring brain temperature changes in health and disease. However, further studies of healthy participants with larger sample size(s) and numerous repeated acquisitions are imperative for establishing a reference range of typical brain TCRE, as well as the threshold above which TCRE is likely pathological.
Background: Magnetic resonance spectroscopic imaging (MRSI) is a neuroimaging technique that may be useful for non-invasive mapping of brain temperature (i.e., thermometry) over a large brain volume. To date, intra-subject reproducibility of MRSI-based brain temperature (MRSI-t) has not been investigated. The objective of this repeated measures MRSI-t study was to establish intra-subject reproducibility and repeatability of brain temperature, as well as typical brain temperature range. Methods: Healthy participants aged 23-46 years (N = 18; 7 females) were scanned at two time points ~12-weeks apart. Volumetric MRSI data were processed by reconstructing metabolite and water images using parametric spectral analysis. Brain temperature was derived using the frequency difference between water and creatine (TCRE) for 47 regions of interest (ROIs) delineated by the modified Automated Anatomical Labeling (AAL) atlas. Reproducibility was measured using the coefficient of variation for repeated measures (COVrep), and repeatability was determined using the standard error of measurement (SEM). For each region, the upper and lower bounds of Minimal Detectable Change (MDC) were established to characterize the typical range of TCRE values. Results: The mean global brain temperature over all subjects was 37.2°C with spatial variations across ROIs. There was a significant main effect for time [F (1, 1,591) = 37.0, p < 0.0001] and for brain region [F (46, 1,591) = 2.66, p < 0.0001]. The time*brain region interaction was not significant [F (46, 1,591) = 0.80, p = 0.83]. Participants' TCRE was stable for each ROI across both time points, with ROIs' COVrep ranging from 0.81 to 3.08% (mean COVrep = 1.92%); majority of ROIs had a COVrep <2.0%. Conclusions: Brain temperature measurements were highly consistent between both time points, indicating high reproducibility and repeatability of MRSI-t. MRSI-t may be a promising diagnostic, prognostic, and therapeutic tool for non-invasively monitoring brain temperature changes in health and disease. However, further studies of healthy participants with larger sample size(s) and numerous repeated acquisitions are imperative for establishing a reference range of typical brain TCRE, as well as the threshold above which TCRE is likely pathological.
Authors: Lorraine Hamelin; Julien Lagarde; Guillaume Dorothée; Claire Leroy; Mickael Labit; Robert A Comley; Leonardo Cruz de Souza; Helene Corne; Luce Dauphinot; Maxime Bertoux; Bruno Dubois; Philippe Gervais; Olivier Colliot; Marie Claude Potier; Michel Bottlaender; Marie Sarazin Journal: Brain Date: 2016-03-15 Impact factor: 13.501
Authors: Christine Ghadery; Laura A Best; Nicola Pavese; Yen Foung Tai; Antonio P Strafella Journal: Curr Neurol Neurosci Rep Date: 2019-05-28 Impact factor: 5.081
Authors: William K Diprose; Catherine A Morgan; Michael Tm Wang; James P Diprose; Joanne C Lin; Sulaiman Sheriff; Doug Campbell; P Alan Barber Journal: J Cereb Blood Flow Metab Date: 2022-06-16 Impact factor: 6.960