Literature DB >> 33422798

A porous layer open-tubular capillary column supported with pepsin and zeolitic imidazolate framework for enantioseparation of four basic drugs in capillary electrochromatography.

Mingxuan Ma1, Cheng Chen1, Xinqi Zhu1, Xiaoqi Li2, Yingxiang Du3, Liu Zhang1, Jie Gan1.   

Abstract

New material zeolitic imidazolate framework-4, 5-imidazoledicarboxylic acid (ZIF-IMD) located on the pore surface of porous layer open-tubular (PLOT) column previously functionalized with N-(3-aminopropyl)-imidazole have been prepared via a layer-by-layer self-assembly strategy. This new ZIF-IMD coating hybrids are used as solid-phase carriers for chiral selector pepsin immobilization. The ZIF-IMD material was characterized by scanning electron microscopy, energy-dispersive spectroscopy, transmission electron microscope and X-ray diffraction. The synthesized pepsin@ZIF-IMD@POLT column achieved the baseline separation of hydroxychloroquine (HCQ), chloroquine (CHQ) and hydroxyzine (HXY) (the resolution of HCQ: 2.19; CHQ: 1.84; HXY: 1.53). Compared with the pepsin@PLOT column (without ZIF-IMD material), the chiral separation capability of the pepsin@ZIF-IMD@POLT column can be remarkably improved. Several key parameters including concentration of chiral selector, buffer pH, applied voltage and buffer concentration were systematically evaluated to provide the optimal enantioseparation condition. The relative standard deviations (RSDs) of intra-day, inter-day, column-to-column and inter-batch of migration time and Rs of the HCQ were evaluated in detail, respectively (RSD < 7.21%). Additionally, the potential mechanism of increased resolution was discussed in the article.
Copyright © 2021. Published by Elsevier B.V.

Entities:  

Keywords:  4,5-imidazoledicarboxylic acid; Capillary electrochromatography; Chiral separation; Organic hybrid coating; PLOT; Zeolitic imidazolate framework

Year:  2020        PMID: 33422798     DOI: 10.1016/j.chroma.2020.461866

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  1 in total

1.  Evaluation of homochiral zeolitic imidazolate framework-8 supported open-tubular column by miniaturized capillary electrochromatography with amperometric detection.

Authors:  Tingting Wang; Li Yang; Yuhuan Cheng; Yulian Zhang; Jiannong Ye; Qingcui Chu; Guifang Cheng
Journal:  Mikrochim Acta       Date:  2021-10-12       Impact factor: 5.833

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.