Literature DB >> 33422725

Impact of prosthetic mitral valve orientation on the ventricular flow field: Comparison using patient-specific computational fluid dynamics.

Jonas Lantz1, Sophia Bäck1, Carl-Johan Carlhäll2, Ann Bolger3, Anders Persson4, Matts Karlsson5, Tino Ebbers6.   

Abstract

Significant mitral valve regurgitation creates progressive adverse remodeling of the left ventricle (LV). Replacement of the failing valve with a prosthesis generally improves patient outcomes but leaves the patient with non-physiological intracardiac flow patterns that might contribute to their future risk of thrombus formation and embolism. It has been suggested that the angular orientation of the implanted valve might modify the postoperative distortion of the intraventricular flow field. In this study, we investigated the effect of prosthetic valve orientation on LV flow patterns by using heart geometry from a patient with LV dysfunction and a competent native mitral valve to calculate intracardiac flow fields with computational fluid dynamics (CFD). Results were validated using in vivo 4D Flow MRI. The computed flow fields were compared to calculations following virtual implantation of a mechanical heart valve oriented in four different angles to assess the effect of leaflet position. Flow patterns were visualized in long- and short-axes and quantified with flow component analysis. In comparison to a native valve, valve implantation increased the proportion of the mitral inflow remaining in the basal region and further increased the residual volume in the apical area. Only slight changes due to valve orientation were observed. Using our numerical framework, we demonstrated quantitative changes in left ventricular blood flow due to prosthetic mitral replacement. This framework may be used to improve design of prosthetic heart valves and implantation procedures to minimize the potential for apical flow stasis, and potentially assist personalized treatment planning.
Copyright © 2020 The Author(s). Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  4D flow CT; Computational fluid dynamics; Computed tomography; Mitral valve; Virtual implantation

Year:  2020        PMID: 33422725     DOI: 10.1016/j.jbiomech.2020.110209

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

Review 1.  Clinical Impact of Computational Heart Valve Models.

Authors:  Milan Toma; Shelly Singh-Gryzbon; Elisabeth Frankini; Zhenglun Alan Wei; Ajit P Yoganathan
Journal:  Materials (Basel)       Date:  2022-05-05       Impact factor: 3.748

2.  CT-Based Simulation of Left Ventricular Hemodynamics: A Pilot Study in Mitral Regurgitation and Left Ventricle Aneurysm Patients.

Authors:  Lukas Obermeier; Katharina Vellguth; Adriano Schlief; Lennart Tautz; Jan Bruening; Christoph Knosalla; Titus Kuehne; Natalia Solowjowa; Leonid Goubergrits
Journal:  Front Cardiovasc Med       Date:  2022-03-22

3.  The impact of 4D-Flow MRI spatial resolution on patient-specific CFD simulations of the thoracic aorta.

Authors:  Zinedine Khatir; Amirul Khan; Malenka Bissell; Molly Cherry
Journal:  Sci Rep       Date:  2022-09-06       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.