Literature DB >> 33422478

Aseptic capillary vitrification of human spermatozoa: Cryoprotectant-free vs. cryoprotectant-included technologies.

Mengying Wang1, Plamen Todorov2, Evgenia Isachenko1, Gohar Rahimi1, Wanxue Wang1, Melanie von Brandenstein3, Pradeep Kumar1, Peter Mallmann1, Vladimir Isachenko4.   

Abstract

The protocol of aseptic cryoprotectant-free vitrification on human spermatozoa is well documented. However, data about the effect of permeable cryoprotectants at this procedure is limited. Presented study aimed to test the aseptic capillary vitrification technologies using permeable cryoprotectant-included or cryoprotectant-free media. Thirty-two normal samples were included and analyzed after vitrification in three different media and thawing. Three treatment groups were formed: Group 1, basic medium; Group 2, basic medium with 0.25 M sucrose; Group 3, basic medium with glycerol. Before plunging into liquid nitrogen, capillaries were filled by 10 μl of spermatozoa suspension and isolated from liquid nitrogen by location in hermetically closed 0.25 ml straws. Progressive motility, plasma membrane integrity, total motility/viability after 24, 48 and 72 h in vitro culture, apoptosis and mitochondrial membrane potential (ΔΨm) were determined after thawing at 42 °C. Progressive motility of spermatozoa in groups 1, 2, 3 was 24.9 ± 1.7%, 34.5 ± 2.8% and 34.0 ± 1.4%, respectively (P1-2,3<0.05). The plasma membrane integrity of spermatozoa in groups 2 and 3 (48.4 ± 2.9% and 45.5 ± 3.9%, respectively) was higher than in Group 1 (33.3 ± 2.1%, P < 0.05). After 24 h, 48 h and 72 h in vitro culture, the total motility and viability of spermatozoa in Group 1 was significantly lower than Group 2 and Group 3. The apoptosis rate in Group 3 (44.5 ± 3.0%) and Group 2 (47.7 ± 4.1%) were lower than in Group 1 (52.5 ± 4.4%; P < 0.05). ΔΨm rates in Group 3 and Group 2 were higher than in Group 1 (P < 0.05) with no statistical differences between this parameter in Group 2 and Group 3 (P > 0.1). In conclusion, supplementation of medium for aseptic capillary technology for cryoprotectant-free vitrification of human spermatozoa by permeable cryoprotectant does not improve the quality of spermatozoa after warming.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aseptic; Capillary; Glycerol; Human spermatozoa; Sucrose; Vitrification

Mesh:

Substances:

Year:  2021        PMID: 33422478     DOI: 10.1016/j.cryobiol.2021.01.006

Source DB:  PubMed          Journal:  Cryobiology        ISSN: 0011-2240            Impact factor:   2.487


  3 in total

1.  Epigenetic Alterations in Cryopreserved Human Spermatozoa: Suspected Potential Functional Defects.

Authors:  Wanxue Wang; Plamen Todorov; Cheng Pei; Mengying Wang; Evgenia Isachenko; Gohar Rahimi; Peter Mallmann; Vladimir Isachenko
Journal:  Cells       Date:  2022-07-04       Impact factor: 7.666

2.  Hydrophobic soot nanoparticles as a non-cytotoxic motility activator of human spermatozoa.

Authors:  Karekin D Esmeryan; Ivaylo Rangelov; Todor A Chaushev
Journal:  Nanoscale Adv       Date:  2022-04-23

3.  Cryoprotectants-Free Vitrification and Conventional Freezing of Human Spermatozoa: A Comparative Transcript Profiling.

Authors:  Mengying Wang; Plamen Todorov; Wanxue Wang; Evgenia Isachenko; Gohar Rahimi; Peter Mallmann; Vladimir Isachenko
Journal:  Int J Mol Sci       Date:  2022-03-11       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.