Literature DB >> 33421036

Improved Reliability of Automated ASPECTS Evaluation Using Iterative Model Reconstruction from Head CT Scans.

Maximilian T Löffler1,2, Nico Sollmann1,3,4, Sebastian Mönch1, Benjamin Friedrich1, Claus Zimmer1, Thomas Baum1, Christian Maegerlein1, Jan S Kirschke1,3.   

Abstract

BACKGROUND AND
PURPOSE: Iterative model reconstruction (IMR) has shown to improve computed tomography (CT) image quality compared to hybrid iterative reconstruction (HIR). Alberta Stroke Program Early CT Score (ASPECTS) assessment in early stroke is particularly dependent on high-image quality. Purpose of this study was to investigate the reliability of ASPECTS assessed by humans and software based on HIR and IMR, respectively.
METHODS: Forty-seven consecutive patients with acute anterior circulation large vessel occlusions (LVOs) and successful endovascular thrombectomy were included. ASPECTS was assessed by three neuroradiologists (one attending, two residents) and by automated software in noncontrast axial CT with HIR (iDose4; 5 mm) and IMR (5 and 0.9 mm). Two expert neuroradiologists determined consensus ASPECTS reading using all available image data including MRI. Agreement between four raters (three humans, one software) and consensus were compared using square-weighted kappa (κ).
RESULTS: Human raters achieved moderate to almost perfect agreement (κ = .557-.845) with consensus reading. The attending showed almost perfect agreement for 5 mm HIR (κHIR  = .845), while residents had mostly substantial agreements without clear trends across reconstructions. Software had substantial to almost perfect agreement with consensus, increasing with IMR 5 and 0.9 mm slice thickness (κHIR  = .751, κIMR  = .777, and κIMR0.9  = .814). Agreements inversely declined for these reconstructions for the attending (κHIR  = .845, κIMR  = .763, and κIMR0.9  = .681).
CONCLUSIONS: Human and software rating showed good reliability of ASPECTS across different CT reconstructions. Human raters performed best with the reconstruction algorithms they had most experience with (HIR for the attending). Automated software benefits from higher resolution with better contrasts in IMR with 0.9 mm slice thickness.
© 2021 The Authors. Journal of Neuroimaging published by Wiley Periodicals LLC on behalf of American Society of Neuroimaging.

Entities:  

Keywords:  Cerebrovascular disease and stroke; computer-assisted image analysis; iterative image reconstruction; middle cerebral artery infarction; multidetector computed tomography

Year:  2021        PMID: 33421036     DOI: 10.1111/jon.12810

Source DB:  PubMed          Journal:  J Neuroimaging        ISSN: 1051-2284            Impact factor:   2.486


  1 in total

1.  Impact of dose reduction and iterative model reconstruction on multi-detector CT imaging of the brain in patients with suspected ischemic stroke.

Authors:  Karolin J Paprottka; Karina Kupfer; Isabelle Riederer; Claus Zimmer; Meinrad Beer; Peter B Noël; Thomas Baum; Jan S Kirschke; Nico Sollmann
Journal:  Sci Rep       Date:  2021-11-15       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.