A novel concentration gradient microfluidic chip for high-throughput antibiotic susceptibility testing of bacteria.

Jiadi Sun1,2, Yijing Ren1, Jian Ji1, Yu Guo1,3, Xiulan Sun4.   

Abstract

Antibiotic resistance has become a serious threat to food safety and public health globally. Therefore, the development of a sensitive, quick, and simple method for antibiotic susceptibility testing is an urgent and crucial need. A novel concentration gradient microfluidic chip was designed in this work to generate antibiotic concentration gradient, culture bacteria, and produce fluorescence emission. An in-house-assembled fluorescence detection platform was constructed, and experiments were conducted to verify the linearity of the generated concentration gradient, explore the appropriate incubation time and flow rate for the microfluidic chip, and study the effect of long-term acid-based food processing on antibiotic susceptibility testing. Experimental results show that the concentration gradient generated by the microfluidic chip exhibited good linearity, stability, and controllability. The appropriate flow rate and incubation time for the microfluidic chip were 2 μL/min and 5 h, respectively. The use of this microfluidic chip for testing antibiotic resistance of Salmonella to ofloxacin and ampicillin generated results that were completely consistent with test results obtained using the gold-standard method. Furthermore, Salmonella showed greater sensitivity to antibiotics under strong acid conditions, confirming the potential influence of acid-based food processing on antibiotic susceptibility testing of real samples. The designed microfluidic chip provides a high-throughput, sensitive, and rapid antibiotic susceptibility testing method that combines the microfluidic chip and the fluorescence detection platform. The application of this method would facilitate determination of antibiotic-resistant bacterial strains for clinicians and researchers, and enable monitoring of changes in bacterial resistance during food processing.

Entities:  

Keywords:  Antibiotic resistance; Concentration gradient; Fluorescence detection; High-throughput test; Microfluidic chip

Mesh:

Substances:

Year:  2021        PMID: 33420534     DOI: 10.1007/s00216-020-03076-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  1 in total

1.  Complete experimental and theoretical characterization of nonlinear concentration gradient generator microfluidic device for analytical purposes.

Authors:  Paulo Henrique Maciel Buzzetti; Maiara Mitiko Taniguchi; Nayara de Souza Mendes; Renata Corrêa Vicentino; Jean Halison de Oliveira; Bento Pereira Cabral Júnior; Marcos de Souza; Johny Paulo Monteiro; Emerson Marcelo Girotto
Journal:  Mikrochim Acta       Date:  2021-12-06       Impact factor: 5.833

  1 in total