Literature DB >> 33415120

3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment.

Ben Asani1, Jakob Siedlecki1, Benedikt Schworm1, Wolfgang J Mayer1, Thomas C Kreutzer1, Nikolaus Luft1, Siegfried G Priglinger1.   

Abstract

Purpose: To assess the efficacy and outcomes of 23-gauge vitreoretinal surgery for rhegmatogenous retinal detachment using a three-dimensional heads-up display (3D HUD) surgical platform as compared to a standard operating microscope (SOM) setting. Design: Retrospective cohort study. Participants: One hundred and forty consecutive eyes of 140 patients with primary retinal detachment.
Methods: All eyes underwent 23-gauge pars plana vitrectomy for primary retinal detachment using either a 3D HUD (NGENUITY; Alcon Inc., Fort Worth, Texas, USA; n = 70 eyes) or a SOM setting (n = 70 eyes); in cases of significant cataract, additional phacoemulsification with intraocular lens (IOL) implantation was performed. Minimum follow-up was 2 months. Main Outcome Measures: Primary retinal reattachment rate, rate of proliferative vitreoretinopathy (PVR), best-corrected visual acuity (BCVA), and duration of surgery.
Results: There were 70 eyes each in the 3D HUD and the SOM group. Both groups did not differ concerning age (p = 0.70), extent of retinal detachment (p = 0.07), number of retinal tears (p = 0.40), macular involvement (p = 0.99), and preoperative BCVA (p = 0.99). Postoperatively, 3D HUD and SOM were comparable concerning the primary retinal reattachment rate (88.6 vs. 94.3%; p = 0.37), the development of postoperative PVR (12.9% vs. 7.1%; p = 0.40) and final BCVA (0.26 ± 0.40 vs. 0.21 ± 0.38 logMAR; p = 0.99). Duration of surgery was significantly longer in the 3D HUD group (66.2 ± 16.5 vs. 61.2 ± 17.1 min; p = 0.04), an effect which however vanished after a "learning curve" of the first 35 eyes (p = 0.49). Conclusions: On par results to a conventional operating microscope can be achieved with a 3D HUD setting when performing 23-gauge vitreoretinal surgery for rhegmatogenous retinal detachment, including the primary retinal reattachment rate, the incidence of postoperative PVR and final BCVA. However, duration of surgery might initially be slightly longer with 3D HUD, suggesting the effect of a learning curve.
Copyright © 2020 Asani, Siedlecki, Schworm, Mayer, Kreutzer, Luft and Priglinger.

Entities:  

Keywords:  3D heads-up display; NGENUITY; operating microscope; rhegmatogenous retinal detachments; vitrectomy

Year:  2020        PMID: 33415120      PMCID: PMC7782350          DOI: 10.3389/fmed.2020.615515

Source DB:  PubMed          Journal:  Front Med (Lausanne)        ISSN: 2296-858X


  17 in total

1.  Macular phototoxicity caused by fiberoptic endoillumination during pars plana vitrectomy.

Authors:  M Michels; H Lewis; G W Abrams; D P Han; W F Mieler; J Neitz
Journal:  Am J Ophthalmol       Date:  1992-09-15       Impact factor: 5.258

2.  Resolving the clinical acuity categories "hand motion" and "counting fingers" using the Freiburg Visual Acuity Test (FrACT).

Authors:  C Lange; N Feltgen; B Junker; K Schulze-Bonsel; M Bach
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-09-03       Impact factor: 3.117

3.  Photic retinal injury from endoillumination during vitrectomy.

Authors:  F Kuhn; R Morris; M Massey
Journal:  Am J Ophthalmol       Date:  1991-01-15       Impact factor: 5.258

4.  HEADS-UP SURGERY FOR VITREORETINAL PROCEDURES: An Experimental and Clinical Study.

Authors:  Claus Eckardt; Erica B Paulo
Journal:  Retina       Date:  2016-01       Impact factor: 4.256

5.  The Preliminary Experiences with Three-Dimensional Heads-Up Display Viewing System for Vitreoretinal Surgery under Various Status.

Authors:  Zhaotian Zhang; Li Wang; Yantao Wei; Dong Fang; Shuxin Fan; Shaochong Zhang
Journal:  Curr Eye Res       Date:  2018-11-14       Impact factor: 2.424

6.  Comparative Analysis of Three-Dimensional Heads-Up Vitrectomy and Traditional Microscopic Vitrectomy for Vitreoretinal Diseases.

Authors:  Ting Zhang; Wenyi Tang; Gezhi Xu
Journal:  Curr Eye Res       Date:  2019-05-15       Impact factor: 2.424

7.  THE INTEGRATIVE SURGICAL THEATER: Combining Intraoperative Optical Coherence Tomography and 3D Digital Visualization for Vitreoretinal Surgery in the DISCOVER Study.

Authors:  Justis P Ehlers; Atsuro Uchida; Sunil K Srivastava
Journal:  Retina       Date:  2018-09       Impact factor: 4.256

8.  Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantation.

Authors:  Wolfgang J Mayer; Thomas Kreutzer; Martin Dirisamer; Christoph Kern; Karsten Kortuem; Efstathios Vounotrypidis; Siegfried Priglinger; Daniel Kook
Journal:  J Cataract Refract Surg       Date:  2017-10-19       Impact factor: 3.351

9.  Higher Risk of Light-Induced Retinal Damage Due to Increase of Intraocular Irradiance by Endoillumination.

Authors:  Philipp S Koelbl; Martin Hessling; Christian Lingenfelder; Sebastian Kupferschmid
Journal:  Ophthalmol Ther       Date:  2018-12-17
View more
  2 in total

1.  Vitrectomy Combined with Cataract Surgery for Retinal Detachment Using a Three-Dimensional Viewing System.

Authors:  Katarzyna Nowomiejska; Mario Damiano Toro; Vincenza Bonfiglio; Aleksandra Czarnek-Chudzik; Agnieszka Brzozowska; Kamil Torres; Robert Rejdak
Journal:  J Clin Med       Date:  2022-03-24       Impact factor: 4.241

2.  Commentary: 3D heads-up surgeries: Backing our backs, and necks!

Authors:  Shrinivas Joshi; Giriraj Vibhute; Guruprasad Ayachit; Apoorva Ayachit
Journal:  Indian J Ophthalmol       Date:  2022-03       Impact factor: 1.848

  2 in total