Literature DB >> 33412561

Reproducibility and normalization of reactive hyperemia using laser speckle contrast imaging.

Behnia Rezazadeh Shirazi1, Rudy J Valentine1, James A Lang1.   

Abstract

BACKGROUND: Impaired perfusion indices signal potential microvascular dysfunction preceding atherosclerosis and other cardiometabolic pathologies. Post-occlusive reactive hyperemia (PORH), a vasodilatory response following a mechanically induced ischemia, is a transient increase in perfusion and can assess microvascular function. The greatest blood flow change corresponding to the first minute of hyperemia (represented by time-to-peak, hyperemic velocity, AUC within 1st min) has been shown to indicate microvascular dysfunction. However, the reproducibility of these temporal kinetic indices of the PORH response is unknown. Our aim was to examine the inter- and intra-day reproducibility and standardization of reactive hyperemia, with emphasis on the kinetic indices of PORH, using laser speckle contrast imaging (LSCI) technique. METHODS AND
RESULTS: Seventeen healthy adults (age = 24 ± 3 years) completed three PORH bouts over two lab visits. LSCI region of interest was a standardized 10 cm region on the dominant ventral forearm. A 5-min brachial artery occlusion period induced by inflating an arm cuff to 200 mmHg, preceded a 4-min hyperemic period. Inter- and intra-day reliability and reproducibility of cutaneous vascular conductance (LSCI flux / mean arterial pressure) were determined using intraclass correlation (ICC) and coefficient of variation (CV%). Maximal flow and area under the curve standardized to zero perfusion showed intra- and inter-day reliability (ICC > 0.70). Time to maximal flow (TMF) was not reproducible (inter-day CV = 18%). However, alternative kinetic indices such as 1-min AUC and overshoot rate-of-change (ORC), represented as a piecewise function (at 5s, 10s, 15s, and 20s into hyperemia), were reproducible (CV< 11%). Biological zero was a reliable normalization point.
CONCLUSION: PORH measured with LSCI is a reliable assessment of microvascular function. However, TMF or its derived hyperemic velocity are not recommended for longitudinal assessment. Piecewise ORC and 1-min AUC are reliable alternatives to assess the kinetic response of PORH.

Entities:  

Mesh:

Year:  2021        PMID: 33412561      PMCID: PMC7790538          DOI: 10.1371/journal.pone.0244795

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


  48 in total

Review 1.  Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging.

Authors:  J D Briers
Journal:  Physiol Meas       Date:  2001-11       Impact factor: 2.833

2.  Relationship between post-occlusive forearm skin reactive hyperaemia and vascular disease in patients with Type 2 diabetes--a novel index for detecting micro- and macrovascular dysfunction using laser Doppler flowmetry.

Authors:  R Yamamoto-Suganuma; Y Aso
Journal:  Diabet Med       Date:  2009-01       Impact factor: 4.359

Review 3.  Non-invasive assessment of skin microvascular function in humans: an insight into methods.

Authors:  Matthieu Roustit; Jean-Luc Cracowski
Journal:  Microcirculation       Date:  2012-01       Impact factor: 2.628

4.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

Review 5.  Laser Speckle Imaging to Monitor Microvascular Blood Flow: A Review.

Authors:  Pedro G Vaz; Anne Humeau-Heurtier; Edite Figueiras; Carlos Correia; Joao Cardoso
Journal:  IEEE Rev Biomed Eng       Date:  2016-02-24

6.  Comparison of laser-Doppler flowmetry with biochemical indicators of endothelial dysfunction related to early microangiopathy in Type 1 diabetic patients.

Authors:  J Skrha; M Prázný; T Haas; J Kvasnicka; B Kalvodová
Journal:  J Diabetes Complications       Date:  2001 Sep-Oct       Impact factor: 2.852

7.  Reproducibility of different laser Doppler fluximetry parameters of postocclusive reactive hyperemia in human forearm skin.

Authors:  Get Bee Yvonne-Tee; Aida Hanum Ghulam Rasool; Ahmad Sukari Halim; Abdul Rashid Abdul Rahman
Journal:  J Pharmacol Toxicol Methods       Date:  2005-01-11       Impact factor: 1.950

8.  Dependence of human forearm skin postocclusive reactive hyperemia on occlusion time.

Authors:  Get Bee Yvonne Tee; Aida Hanum Ghulam Rasool; Ahmad Sukari Halim; Abdul Rashid Abdul Rahman
Journal:  J Pharmacol Toxicol Methods       Date:  2004 Jul-Aug       Impact factor: 1.950

9.  Cyclooxygenase and nitric oxide synthase dependence of cutaneous reactive hyperemia in humans.

Authors:  Marvin S Medow; Indu Taneja; Julian M Stewart
Journal:  Am J Physiol Heart Circ Physiol       Date:  2007-03-16       Impact factor: 4.733

10.  Involvement of cytochrome epoxygenase metabolites in cutaneous postocclusive hyperemia in humans.

Authors:  Jean-Luc Cracowski; Florence Gaillard-Bigot; Claire Cracowski; Claire Sors; Matthieu Roustit; Claire Millet
Journal:  J Appl Physiol (1985)       Date:  2012-11-21
View more
  1 in total

1.  Characterizing tourniquet induced hemodynamics during total knee arthroplasty using diffuse optical spectroscopy.

Authors:  George P Philipopoulos; Behnam Sharareh; Goutham Ganesan; Bruce J Tromberg; Thomas D O'Sullivan; Ran Schwarzkopf
Journal:  J Orthop Res       Date:  2022-03-15       Impact factor: 3.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.