The Two-Zone model is used in occupational hygiene to predict both near-field and far-field airborne contaminant concentrations. A literature review was carried out on 21 scientific publications in which the Two-Zone model was used to assess occupational exposure to solvent vapors. Data on exposure scenarios, solvents, generation/emission rates, near- and far-field parameters, and model performance were collected and analyzed. Over the 24 exposure scenarios identified, 18 were evaluated under controlled conditions, 5 under normal workplace activities, and 1 was reported based on literature data. The scenarios involved a variety of tasks which consisted, mostly, of cleaning metal parts, spraying solvents onto surfaces, spilling liquids, and filling containers with volatile substances. Twenty-eight different solvents were modeled and the most commonly tested were benzene, toluene, and acetone. Emission rates were considered constant in 16 scenarios, exponentially decreasing in 6 scenarios, and intermittent in 2 scenarios. Four-hundred-and-forty-six (446) predicted-to-measured concentration ratios were calculated across the 21 studies; 441 were obtained in controlled conditions, 4 under normal workplace activities, and 1 was calculated based on the literature data. For controlled studies, the Two-Zone model predictive performance was within a factor of 0.3-3.7 times the measured concentrations with 93% of the values between 0.5 and 2. The model overestimated the measured concentrations in 63% of the evaluations. The median predicted concentration for the near-field was 1.38 vs. 1.02 for the far-field. Results suggest that the model might be a useful tool for predicting occupational exposure to vapors of solvents by providing a conservative approach. Harmonization in model testing strategies and data presentation is needed in future studies to improve the assessment of the predictability of the Two-Zone model. Moreover, this review has provided a database of exposure scenarios, input parameter values, and model predictive performances which can be useful to occupational hygienists in their future modeling activities.

Entities:  

Keywords:  Exposure assessment; Two-Box model; Two-Zone model; mathematical modeling; model performance testing; occupational exposure solvent vapors

Year:  2021        PMID: 33412086     DOI: 10.1080/15459624.2020.1861283

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  2 in total

1.  Estimating Inhalation Exposure Resulting from Evaporation of Volatile Multicomponent Mixtures Using Different Modelling Approaches.

Authors:  Martin Tischer; Michael Roitzsch
Journal:  Int J Environ Res Public Health       Date:  2022-02-10       Impact factor: 4.614

2.  Quantifying Emission Factors and Setting Conditions of Use According to ECHA Chapter R.14 for a Spray Process Designed for Nanocoatings-A Case Study.

Authors:  Antti Joonas Koivisto; Benedetta Del Secco; Sara Trabucco; Alessia Nicosia; Fabrizio Ravegnani; Marko Altin; Joan Cabellos; Irini Furxhi; Magda Blosi; Anna Costa; Jesús Lopez de Ipiña; Franco Belosi
Journal:  Nanomaterials (Basel)       Date:  2022-02-10       Impact factor: 5.076

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.