Literature DB >> 33409545

Electromagnetic Navigation System-Guided Microwave Ablation of Hepatic Tumors: A Matched Cohort Study.

K I Ringe1, G H Pöhler2, H Rabeh3, F Wacker2.   

Abstract

PURPOSE: To assess the accuracy and applicability of an electromagnetic navigation system (EMNS) for CT-guided microwave ablation (MWA) of hepatic tumors in comparison with conventional CT-guidance.
MATERIALS AND METHODS: 34 patients (m = 20/f = 14, mean age 34 y) with 34 liver tumors (primary = 22, metastases = 14, mean size 20 mm) referred for CT-guided MWA were included in this IRB-approved study. Interventions were performed prospectively using an EMNS in 17 patients (navigation group), and results were compared to a matched historic cohort of 17 patients using conventional CT-guidance (control group, t-test, p < 0.05 deemed significant). Primary outcome measurement: accuracy of antenna placement (deviation). Secondary outcome measurements: setup time, number of control scans, duration and radiation exposure for antenna placement.
RESULTS: Ablations were performed using a single or a double-angulated approach. Application of the EMNS was feasible in 14 cases (82%). Mean total deviation of the antenna feed point in the navigation and control group was 2.4 mm (range 0.2-4.8 mm) and 3.9 mm (range 0.4-7.8 mm), p < 0.05. Mean setup time for the EMNS was 6.75 ± 3.9 min (range 3-12 min). Mean number of control scans in the navigation and control group was 3 ± 0.9 (range 1-4) and 6 ± 1.3 (range 4-8), p < 0.0001; mean time for antenna placement was 9 ± 7.3 min (range 1.4-25.9 min) and 11.45 ± 6.1 min (range 3.9-27.4 min), p = 0.3164. Radiation exposure was significantly less in the navigation group.
CONCLUSION: Our experience in a limited number of patients suggests that EMNS enables intuitive CT-guided MWA of liver tumors with higher accuracy when compared to ablations performed without navigation and with fewer control scans needed.

Entities:  

Keywords:  Accuracy; Computed tomography; Electromagnetic; Microwave ablation; Navigation

Mesh:

Year:  2021        PMID: 33409545     DOI: 10.1007/s00270-020-02761-6

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  2 in total

Review 1.  Precision Imaging Guidance in the Era of Precision Oncology: An Update of Imaging Tools for Interventional Procedures.

Authors:  Chiara Floridi; Michaela Cellina; Giovanni Irmici; Alessandra Bruno; Nicolo' Rossini; Alessandra Borgheresi; Andrea Agostini; Federico Bruno; Francesco Arrigoni; Antonio Arrichiello; Roberto Candelari; Antonio Barile; Gianpaolo Carrafiello; Andrea Giovagnoni
Journal:  J Clin Med       Date:  2022-07-12       Impact factor: 4.964

2.  Impact of an Augmented Reality Navigation System (SIRIO) on Bone Percutaneous Procedures: A Comparative Analysis with Standard CT-Guided Technique.

Authors:  Eliodoro Faiella; Gennaro Castiello; Caterina Bernetti; Giuseppina Pacella; Carlo Altomare; Flavio Andresciani; Bruno Beomonte Zobel; Rosario Francesco Grasso
Journal:  Curr Oncol       Date:  2021-05-08       Impact factor: 3.677

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.