Literature DB >> 3340729

Thermoluminescence dosimetry of gamma rays from the atomic bomb at Hiroshima using the predose technique.

T Nagatomo1, Y Ichikawa, H Ishii, M Hoshi.   

Abstract

Thermoluminescence dosimetry measurements of gamma rays produced by the atomic bomb in Hiroshima were made by the predose technique using eight ceramic samples collected from five buildings located at distances between 1271 and 2051 m from the hypocenter. The results of our measurements are compared to both the newer dose estimates (Dosimetry System 1986) and older dose estimates (Tentative 1965 Doses) for survivors of the Hiroshima atomic bomb. In comparison with the older estimates, our results are larger by a factor of 2.3 at 1271 m and 3.9 at 2051 m. Our results and the newer estimates for Hiroshima differ by a factor of only 1.14 +/- 0.16 on the average.

Entities:  

Mesh:

Year:  1988        PMID: 3340729

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  1 in total

1.  Prospects and status of the dosimetry system for atomic bomb survivor cohort study conducted at Research Institute for Radiation Biology and Medicine of Hiroshima University.

Authors:  Seiko Hirota; Hiroshi Yasuda; Hideshi Kawakami; Shinji Yoshinaga
Journal:  J Radiat Res       Date:  2021-05-05       Impact factor: 2.724