Literature DB >> 33406154

Development and evaluation of a multiplex loop-mediated isothermal amplification (LAMP) assay for differentiation of Mycobacterium tuberculosis and non-tuberculosis mycobacterium in clinical samples.

Jeeyong Kim1, Borae G Park1, Da Hye Lim1, Woong Sik Jang1, Jeonghun Nam1, Do-CiC Mihn2, Chae Seung Lim1.   

Abstract

INTRODUCTION: The rapid and accurate diagnosis of tuberculosis (TB) is important to reduce morbidity and mortality rates and risk of transmission. Therefore, molecular detection methods such as a real-time PCR-based assay for Mycobacterium tuberculosis (MTB) have been commonly used for diagnosis of TB. Loop-mediated isothermal amplification (LAMP) assay was believed to be a simple, quick, and cost-effective isothermal nucleic acid amplification diagnostic test for infectious diseases. In this study, we designed an in-house multiplex LAMP assay for the differential detection of MTB and non-tuberculosis mycobacterium (NTM), and evaluated the assay using clinical samples.
MATERIAL AND METHODS: For the multiplex LAMP assay, two sets of specific primers were designed: the first one was specific for IS6110 genes of MTB, and the second one was universal for rpoB genes of mycobacterium species including NTM. MTB was confirmed with a positive reaction with both primer sets, and NTM was identified with a positive reaction by only the second primer set without a MTB-specific reaction. Total 333 clinical samples were analyzed to evaluate the multiplex LAMP assay. Clinical samples were composed of 195 positive samples (72 MTB and 123NTM) and 138 negative samples. All samples were confirmed positivity or negativity by real-time PCR for MTB and NTM. Analytical sensitivity and specificity were evaluated for the multiplex LAMP assay in comparison with acid fast bacilli staining and the culture method.
RESULTS: Of 123 NTM samples, 121 were identified as NTM and 72/72 MTB were identified as MTB by the multiplex LAMP assay. False negative reactions were seen only in two NTM positive samples with co-infection of Candida spp. All 138 negative samples were identified as negative for MTB and NTM. Analytical sensitivity of the multiplex LAMP assay was 100% (72/72) for MTB, and 98.4% (121/123) for NTM. And the specificity of assay was 100% (138/138) for all.
CONCLUSIONS: Our newly designed multiplex LAMP assay for MTB and NTM showed relatively good sensitivity in comparison with previously published data to detect isolated MTB. This multiplex LAMP assay is expected to become a useful tool for detecting and differentiating MTB from NTM rapidly at an acceptable sensitivity.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33406154      PMCID: PMC7787462          DOI: 10.1371/journal.pone.0244753

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


  11 in total

Review 1.  Systematic review: Comparison of Xpert MTB/RIF, LAMP and SAT methods for the diagnosis of pulmonary tuberculosis.

Authors:  Liping Yan; Heping Xiao; Qing Zhang
Journal:  Tuberculosis (Edinb)       Date:  2015-11-30       Impact factor: 3.131

2.  Evaluation of three real-time PCR assays for differential identification of Mycobacterium tuberculosis complex and nontuberculous mycobacteria species in liquid culture media.

Authors:  Yu Jung Jung; Ji-Youn Kim; Dong Joon Song; Won-Jung Koh; Hee Jae Huh; Chang-Seok Ki; Nam Yong Lee
Journal:  Diagn Microbiol Infect Dis       Date:  2016-03-15       Impact factor: 2.803

Review 3.  The rapid molecular test Xpert MTB/RIF ultra: towards improved tuberculosis diagnosis and rifampicin resistance detection.

Authors:  O Opota; J Mazza-Stalder; G Greub; K Jaton
Journal:  Clin Microbiol Infect       Date:  2019-03-28       Impact factor: 8.067

4.  Comparison of NaOH-N-acetyl cysteine and sulfuric acid decontamination methods for recovery of mycobacteria from clinical specimens.

Authors:  Patricia C A M Buijtels; Pieter L C Petit
Journal:  J Microbiol Methods       Date:  2005-07       Impact factor: 2.363

5.  Official American Thoracic Society/Infectious Diseases Society of America/Centers for Disease Control and Prevention Clinical Practice Guidelines: Diagnosis of Tuberculosis in Adults and Children.

Authors:  David M Lewinsohn; Michael K Leonard; Philip A LoBue; David L Cohn; Charles L Daley; Ed Desmond; Joseph Keane; Deborah A Lewinsohn; Ann M Loeffler; Gerald H Mazurek; Richard J O'Brien; Madhukar Pai; Luca Richeldi; Max Salfinger; Thomas M Shinnick; Timothy R Sterling; David M Warshauer; Gail L Woods
Journal:  Clin Infect Dis       Date:  2016-12-08       Impact factor: 9.079

Review 6.  Tuberculosis.

Authors:  Jennifer Furin; Helen Cox; Madhukar Pai
Journal:  Lancet       Date:  2019-03-20       Impact factor: 79.321

Review 7.  Epidemiology of human pulmonary infection with nontuberculous mycobacteria: a review.

Authors:  D Rebecca Prevots; Theodore K Marras
Journal:  Clin Chest Med       Date:  2014-11-06       Impact factor: 2.878

8.  Real-time Detection and Monitoring of Loop Mediated Amplification (LAMP) Reaction Using Self-quenching and De-quenching Fluorogenic Probes.

Authors:  Vijay J Gadkar; David M Goldfarb; Soren Gantt; Peter A G Tilley
Journal:  Sci Rep       Date:  2018-04-03       Impact factor: 4.379

9.  Epidemiology of Nontuberculous Mycobacterial Infection, South Korea, 2007-2016.

Authors:  Hyewon Lee; Woojae Myung; Won-Jung Koh; Seong Mi Moon; Byung Woo Jhun
Journal:  Emerg Infect Dis       Date:  2019-03       Impact factor: 6.883

Review 10.  Effectiveness of real-time polymerase chain reaction assay for the detection of Mycobacterium tuberculosis in pathological samples: a systematic review and meta-analysis.

Authors:  Emmanuel O Babafemi; Benny P Cherian; Lee Banting; Graham A Mills; Kandala Ngianga
Journal:  Syst Rev       Date:  2017-10-25
View more
  3 in total

1.  eDNA-based detection of the invasive crayfish Pacifastacus leniusculus in streams with a LAMP assay using dependent replicates to gain higher sensitivity.

Authors:  David Porco; Sylvie Hermant; Chanistya Ayu Purnomo; Mario Horn; Guy Marson; Guy Colling
Journal:  Sci Rep       Date:  2022-04-21       Impact factor: 4.996

Review 2.  Recent advances in loop-mediated isothermal amplification (LAMP) for rapid and efficient detection of pathogens.

Authors:  Nupur Garg; Farhan Jalees Ahmad; Sudeshna Kar
Journal:  Curr Res Microb Sci       Date:  2022-02-23

3.  An HFman Probe-Based Multiplex Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Simultaneous Detection of Hantaan and Seoul Viruses.

Authors:  Yi Zeng; Yun Feng; Yongjuan Zhao; Xiaoling Zhang; Lifen Yang; Juan Wang; Zihou Gao; Chiyu Zhang
Journal:  Diagnostics (Basel)       Date:  2022-08-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.