Literature DB >> 33403786

Endobronchial coil spring fiducial markers for CyberKnife® stereotactic body radiation therapy.

Alessio Casutt1, Leslie Noirez1, Maurizio Bernasconi2, Angela Koutsokera1, Catherine Beigelman-Aubry3, Rémy Kinj4, Esat-Mahmut Ozsahin4, André-Dante Durham4, Christophe von Garnier1, Alban Lovis1.   

Abstract

BACKGROUND AND
OBJECTIVE: SBRT is an alternative treatment for early-stage inoperable lung cancer. Metallic FM allow to increase tumour tracking precision by CyberKnife®. Currently used techniques for FM placement have many limitations; transthoracic insertion has a high risk for pneumothorax, endovascular insertion requires expertise and dedicated angiography infrastructure and endobronchial linear-gold FM dislocate frequently. This is the first study to assess the safety and efficacy of cs-FM endobronchial insertion under fluoroscopy with or without R-EBUS assessment.
METHODS: We retrospectively evaluated all consecutive patients undergoing endobronchial cs-FM placement for at least one PPL <25 mm between 10.2015 and 12.2019. TBB of the PPL were performed in case of a typical R-EBUS signal. PPL tracking accuracy by CyberKnife, complications, cs-FM migration rate and procedure duration were analysed.
RESULTS: A total of 52 patients were treated during 55 procedures and 207 cs-FM were placed in 70 PPL. Tracking was successful for 65 of 70 (93%) PPL. R-EBUS was performed for 33 (47%) PPL and TBB for 9 (13%) PPL. Bronchospasm occurred once and any other complications were observed. Migration of cs-FM occurred in 16 of 207 (8%) cs-FM. Migration was more frequent when the target was in a previously irradiated area (P = 0.022). The median bronchoscopy duration was 31.5 min (n = 48 procedures).
CONCLUSION: Bronchoscopic cs-FM placement is a rapid and safe procedure. It is associated with a low migration rate and allows precise SBRT delivery. Previous irradiation of the PPL was associated with a higher migration rate.
© 2021 Asian Pacific Society of Respirology.

Entities:  

Keywords:  airway markers; bronchoscopy and interventional techniques; lung cancer; metallic fiducial marker; stereotactic body radiation therapy

Year:  2021        PMID: 33403786     DOI: 10.1111/resp.14006

Source DB:  PubMed          Journal:  Respirology        ISSN: 1323-7799            Impact factor:   6.424


  2 in total

1.  Precisely translating computed tomography diagnosis accuracy into therapeutic intervention by a carbon-iodine conjugated polymer.

Authors:  Mingming Yin; Xiaoming Liu; Ziqiao Lei; Yuting Gao; Jiacheng Liu; Sidan Tian; Zhiwen Liang; Ye Wang; Fanling Meng; Liang Luo
Journal:  Nat Commun       Date:  2022-05-12       Impact factor: 17.694

2.  Clinical Evaluation of Fiducial Marker Pre-Planning for Virtual Bronchoscopic Navigation Implantation in Lung Tumour Patients Treated With CyberKnife.

Authors:  Ki Man Ku; Bing Lam; Vincent W C Wu; Kwok Ting Chan; Chloe Y Y Chan; H C Cheng; Kamy M Y Yuen; Jing Cai
Journal:  Front Oncol       Date:  2022-06-16       Impact factor: 5.738