Raghav R Mattay1, Richard Shlansky-Goldberg2, Bryan A Pukenas2. 1. Department of Radiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA, 19104, USA. rrmattay@gmail.com. 2. Department of Radiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA, 19104, USA.
Abstract
BACKGROUND: Although not standard of care, Cystic Fibrosis patients with recurrent hemoptysis occasionally have coil embolization of bronchial arteries. In the event of recanalization of these arteries in this specific subset of patients, the presence of indwelling coils makes the prospect of conventional particle embolization more difficult, preventing both adequate catheterization of the coiled segment and reflux of the particles. CASE PRESENTATION: In this report, we describe a case of bronchial artery embolization of a complex Cystic Fibrosis patient with massive hemoptysis from recanalized coiled bronchial arteries utilizing a Scepter Balloon Catheter® (Microvention Terumo, USA) in administration of the liquid embolic agent Onyx® (Medtronic, USA). CONCLUSIONS: The Scepter occlusion balloon catheter allowed for careful placement of the tip within the interstices of the pre-existing coils, allowing for Onyx injection directly into the coil mass without reflux, reconfirming the benefits of Onyx embolization in bronchial artery embolization and providing evidence that the Scepter occlusion balloon catheter should be added to the armamentarium of devices used in complex bronchial artery embolization for Cystic Fibrosis patients with massive hemoptysis.
BACKGROUND: Although not standard of care, Cystic Fibrosispatients with recurrent hemoptysis occasionally have coil embolization of bronchial arteries. In the event of recanalization of these arteries in this specific subset of patients, the presence of indwelling coils makes the prospect of conventional particle embolization more difficult, preventing both adequate catheterization of the coiled segment and reflux of the particles. CASE PRESENTATION: In this report, we describe a case of bronchial artery embolization of a complex Cystic Fibrosispatient with massive hemoptysis from recanalized coiled bronchial arteries utilizing a Scepter Balloon Catheter® (Microvention Terumo, USA) in administration of the liquid embolic agent Onyx® (Medtronic, USA). CONCLUSIONS: The Scepter occlusion balloon catheter allowed for careful placement of the tip within the interstices of the pre-existing coils, allowing for Onyx injection directly into the coil mass without reflux, reconfirming the benefits of Onyx embolization in bronchial artery embolization and providing evidence that the Scepter occlusion balloon catheter should be added to the armamentarium of devices used in complex bronchial artery embolization for Cystic Fibrosispatients with massive hemoptysis.
Authors: Isabelle Ayx; René Müller-Wille; Walter A Wohlgemuth; Michael Pfeifer; Marc Lepiorz; Heinrich Hubauer; Holger Goessmann; Christian Stroszczynski; Niels Zorger Journal: J Vasc Interv Radiol Date: 2017-03-06 Impact factor: 3.464
Authors: Joachim Kettenbach; Harald Ittrich; Jean Yves Gaubert; Bernhard Gebauer; Jan Albert Vos Journal: Cardiovasc Intervent Radiol Date: 2022-04-08 Impact factor: 2.740