Anjali Singal1, Daisy Sahni2, Tulika Gupta2, Anjali Aggarwal2, Ashok Kumar Gupta3. 1. Department of Anatomy, All India Institute of Medical Sciences, Bathinda, Punjab, 151001, India. anjali_singal@rediffmail.com. 2. Department of Anatomy, Postgraduate Institute of Medical Education and Research, Chandigarh, India. 3. Department of Otorhinolaryngology and Head-Neck Surgery, Fortis Hospital, Mohali, Punjab, India.
Abstract
PURPOSE: The purpose of this investigation was to evaluate the relation of the basal turn of cochlea with middle cranial fossa and round window as pertaining to middle cranial fossa cochlear implant technique. METHODS: Fifty-four formalin preserved temporal bones were micro-dissected to expose the basal turn. The point (f) was marked on the basal turn of cochlea where there was minimum distance of basal turn of cochlea from the floor of middle cranial fossa (f1). The f-f1 distance, the angle (∠smf) and distance of point "f" from the round window (s-f) was measured. RESULTS: The mean minimum distance between basal turn of cochlea and floor of middle cranial fossa (f-f1) was 2.0 ± 0.7 mm.The point f was at mean distance (s-f) and angle (∠smf) of 14.7 ± 1.6 mm and 217° ± 13.7° from round window, respectively. CONCLUSIONS: The information may be helpful for designing appropriate electrode array for middle fossa technique especially for deciding the length of electrode array towards round window, as otherwise electrode may extend into vestibule of inner ear. In the cases where bone thickness between superior part of basal turn of cochlea and middle cranial fossa is < 1.5 mm, surgeon should be extra cautious.
PURPOSE: The purpose of this investigation was to evaluate the relation of the basal turn of cochlea with middle cranial fossa and round window as pertaining to middle cranial fossa cochlear implant technique. METHODS: Fifty-four formalin preserved temporal bones were micro-dissected to expose the basal turn. The point (f) was marked on the basal turn of cochlea where there was minimum distance of basal turn of cochlea from the floor of middle cranial fossa (f1). The f-f1 distance, the angle (∠smf) and distance of point "f" from the round window (s-f) was measured. RESULTS: The mean minimum distance between basal turn of cochlea and floor of middle cranial fossa (f-f1) was 2.0 ± 0.7 mm.The point f was at mean distance (s-f) and angle (∠smf) of 14.7 ± 1.6 mm and 217° ± 13.7° from round window, respectively. CONCLUSIONS: The information may be helpful for designing appropriate electrode array for middle fossa technique especially for deciding the length of electrode array towards round window, as otherwise electrode may extend into vestibule of inner ear. In the cases where bone thickness between superior part of basal turn of cochlea and middle cranial fossa is < 1.5 mm, surgeon should be extra cautious.
Authors: Juan Carlos Cisneros Lesser; Rubens Vuono de Brito Neto; Graziela de Souza Queiroz Martins; Ricardo Ferreira Bento Journal: Int Arch Otorhinolaryngol Date: 2016-04-08