Literature DB >> 33397336

Accuracy of fluoroscopic examination in the treatment of Bennett's fracture.

Yaobin Yin1, Yanqing Wang1, Zhilong Wang1, Wenrui Qu1, Wen Tian1, Shanlin Chen2.   

Abstract

BACKGROUND: Restoration of joint congruity is an important factor for the prevention of subsequent arthritis in patients with Bennett's fracture. Surgical treatment of Bennett's fracture is thus generally recommended for displaced intra-articular fractures to the proximal aspect of the thumb metacarpal. Fluoroscopic examination is used to evaluate the adequacy of closed reduction after pinning of Bennett's fracture. The purpose of this study was to determine the accuracy of fluoroscopy to determine the reduction of Bennett's fractures.
METHODS: A model was created, to mimic a Bennett's fracture utilizing ten fresh-frozen cadaveric hands. An oblique cut was made in the proximal aspect of the thumb metacarpal using an oscillating saw. The small oblique fragment involved 1/4-1/3 of the joint surface was then shifted in position creating a step-off or gap at the fracture site. An anatomical reduction model, gap models (1 mm, 2 mm, 3 mm), and step-off models (1 mm, 2 mm, 3 mm) were created using percutaneous fixation with two 1.0 mm Kirschner wires for each cadaveric hand. Fluoroscopic assessment then took place and was reviewed by 2 attending hand surgeons blinded to the actual position. Their estimated fluoroscopic position was then compared to the actual displacement.
RESULTS: The step-off and gap on fluoroscopic examination showed a significant difference compared to the step-off and gap from direct visualization. The frequency of underestimation for the 3 mm displacement models from the fluoroscopic examination was 60%. The frequency for overestimated was 9% for the models in which displacement was within 2 mm (0, 1, 2 mm).
CONCLUSIONS: The assessment of articular gap and step-off using PA (postero-anterior), AP (antero-posterior), and lateral view of fluoroscopic examination is not accurate as compared to the examination by direct visualization. Surgeons need to be aware that PA, AP and lateral view of fluoroscopic examination alone may not be sufficient to judge the final position of a reduced Bennett's fracture. Other methods such as live fluoroscopy in multiple different planes, 3-dimensional fluoroscopy or arthroscopic examination should be considered.

Entities:  

Keywords:  Bennett’s fracture; Fluoroscopy; Gap; Reduction; Step-off

Mesh:

Year:  2021        PMID: 33397336      PMCID: PMC7783999          DOI: 10.1186/s12891-020-03867-1

Source DB:  PubMed          Journal:  BMC Musculoskelet Disord        ISSN: 1471-2474            Impact factor:   2.362


  24 in total

1.  Closed reduction intermetacarpal Kirschner wire fixation in the treatment of unstable fractures of the base of the first metacarpal.

Authors:  A P A Greeven; T D W Alta; R E M Scholtens; P de Heer; F M van der Linden
Journal:  Injury       Date:  2011-12-09       Impact factor: 2.586

2.  The conservative management of Bennett's fracture-dislocation: a 26-year follow-up.

Authors:  P J Livesley
Journal:  J Hand Surg Br       Date:  1990-08

3.  Treatment of a Bennett fracture using tension band wiring.

Authors:  Xu Zhang; Xinzhong Shao; Zhijie Zhang; Sumin Wen; Jianxin Sun; Bin Wang
Journal:  J Hand Surg Am       Date:  2012-02-02       Impact factor: 2.230

4.  Long-term patient-reported outcomes following Bennett's fractures.

Authors:  S D Middleton; N McNiven; E J Griffin; R E Anakwe; C W Oliver
Journal:  Bone Joint J       Date:  2015-07       Impact factor: 5.082

5.  [The intermetacarpal double pinning in the surgical treatment of Bennett fracture (report of 24 cases)].

Authors:  A Bennani; S Zizah; M Benabid; S Almoubaker; B Chbani; K Lahrach; A Marzouki; F Boutayeb
Journal:  Chir Main       Date:  2012-05-11

6.  Nonoperative treatment of Bennett's fracture: a 13-year follow-up.

Authors:  C J Oosterbos; H H de Boer
Journal:  J Orthop Trauma       Date:  1995-02       Impact factor: 2.512

7.  Bennett fracture: Arthroscopically assisted percutaneous screw fixation versus open surgery: Functional and radiological outcomes.

Authors:  G Pomares; C Strugarek-Lecoanet; F Dap; G Dautel
Journal:  Orthop Traumatol Surg Res       Date:  2016-03-15       Impact factor: 2.256

8.  Accuracy of fluoroscopy in closed reduction and percutaneous fixation of simulated Bennett's fracture.

Authors:  John T Capo; Tosca Kinchelow; Nathaniel S Orillaza; William Rossy
Journal:  J Hand Surg Am       Date:  2009-04       Impact factor: 2.230

9.  Operative treatment of Bennett's fracture.

Authors:  Roman Pavić; Mario Malović
Journal:  Coll Antropol       Date:  2013-03

10.  Bennett's fracture.

Authors:  K Kjaer-Petersen; O Langhoff; K Andersen
Journal:  J Hand Surg Br       Date:  1990-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.