Literature DB >> 33396060

Carboxyl-functionalized hollow polymer microspheres for detection of trace metal elements in complex food matrixes by ICP-MS assisted with solid-phase extraction.

Jiaxing Qin1, Zheng Su1, Yuehui Mao1, Cuicui Liu2, Bin Qi2, Guozhen Fang3, Shuo Wang4.   

Abstract

In this work, carboxyl-functionalized hollow polymer microspheres (CHPMs) was successfully fabricated using poly (styrene-itaconic anhydride) particles as the core template and itaconic anhydride and trans-anethole cross-linked with divinylbenzene as the shell. The desirable microspheres and hollow structure of CHPMs were demonstrated by scanning and transmission electron microscopies, respectively. The characterized CHPMs as an adsorbent was packed into a solid phase extraction column to simultaneously detect the V(V), Cr(III), Cu(II), Cd(II), and Pb(II) in digested food samples by inductively coupled plasma-mass spectrometry (ICP-MS). A series of experimental parameters of solid-phase extraction (SPE) were investigated through vast experiments to improve sensitivity of the proposed method in metal ions detection. The detection limits of the method reached 0.8-3.2 ng L-1 for the target elements, and the relative standard deviations (RSDs) ranging from 1.2% to 3.5% were obtained from eleven parallel experiments using a 1.0 μg L-1 sample solution. The stability allowed the material to withstand more than 15 cycling while the recoveries remained above 88%. In food samples, the detection limits were at 0.20-0.80 μg kg-1, and satisfactory recoveries of 85-104% were obtained in spike tests of laver, fish as well as chicken.
Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Carboxyl-functionalized hollow polymer microspheres; Digested food samples; ICP-MS; Metal ions detection; Solid-phase extraction

Mesh:

Substances:

Year:  2020        PMID: 33396060     DOI: 10.1016/j.ecoenv.2020.111729

Source DB:  PubMed          Journal:  Ecotoxicol Environ Saf        ISSN: 0147-6513            Impact factor:   6.291


  2 in total

1.  Fluorescence detection of malachite green and cations (Cr3+, Fe3+ and Cu2+) by a europium-based coordination polymer.

Authors:  Ya-Jie Kong; Guo-Zheng Hou; Zhao-Ning Gong; Feng-Tan Zhao; Li-Juan Han
Journal:  RSC Adv       Date:  2022-03-17       Impact factor: 3.361

2.  Nutritional Changes and Early Warning of Moldy Rice under Different Relative Humidity and Storage Temperature.

Authors:  Jing Du; Yingxue Lin; Yuan Gao; Yanyan Tian; Jixiang Zhang; Guozhen Fang
Journal:  Foods       Date:  2022-01-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.