Literature DB >> 3339062

Revision of total hip replacement for primary osteoarthritis.

R Johnsson1, K G Thorngren, B M Persson.   

Abstract

During the 11-year-period from 1970 to 1980, 799 total hip arthroplasties with metal-on-plastic prostheses were performed for primary osteoarthritis. In all cases high viscosity cement was used, but not under pressure; acetabular cartilage was removed, but the femoral canal was not plugged. The rate of revision and risk factors were evaluated by survivorship analysis. The overall cumulative revision rates were 11%, 14% and 19% after 8, 10, and 14 years respectively. When prophylactic antibiotics were not used, there was a significant risk of revision for infection. The risk of revision for mechanical loosening of both the acetabular and femoral components was significantly increased for men, younger patients, and if a snap-fit prosthesis with a 35 mm head and short wedged stem was used. The survivorship findings were validated by multivariate statistical analysis.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3339062

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  2 in total

1.  Function after total hip replacement for primary osteoarthritis.

Authors:  R Johnsson; K G Thorngren
Journal:  Int Orthop       Date:  1989       Impact factor: 3.075

Review 2.  Patient characteristics affecting the prognosis of total hip and knee joint arthroplasty: a systematic review.

Authors:  Pasqualina L Santaguida; Gillian A Hawker; Pamela L Hudak; Richard Glazier; Nizar N Mahomed; Hans J Kreder; Peter C Coyte; James G Wright
Journal:  Can J Surg       Date:  2008-12       Impact factor: 2.089

  2 in total