Literature DB >> 33390319

[Management of image guidance doses delivered during radiotherapy].

G Delpon1, D Lazaro2, R de Crevoisier3.   

Abstract

Image-guided radiotherapy (IGRT) has become a standard irradiation technique to improve the clinical outcome of patients in terms of toxicity and local control due to better targeting of radiation during the irradiation fraction. Positioning imaging systems, whether embedded or not, such as kV for 2×2D acquisitions and especially kVCBCT for 3D acquisitions are however irradiating in a large volume including the target volume but also healthy tissue, with a theoretical risk of increased toxicity and second cancer. It therefore appears very important both to optimize the absorbed dose due to IGRT practice but also to report it, especially in case of kVCBCT. The AAPM report published in 2018 (« Image guidance doses delivered during radiotherapy: Quantification, management, and reduction ») proposes a management of image guidance doses delivered during radiotherapy. This report is the basis of this focus article that aims at giving orders of magnitude and proposing a management of image guidance doses delivered during radiotherapy in clinical practice. The dose delivered per kVCBCT is about 0.5 to 2 cGy at isocenter according to treatment site. As long as the calculation algorithms are not available in the treatment planning systems, it seems appropriate to use at least the published dose orders of magnitude. This estimate should ultimately allow the clinician to decide on the therapeutic strategy in the event of accumulation of positioning imaging sessions.
Copyright © 2020 Société française de radiothérapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Dose; IGRT; Positionnement; Radiothérapie guidée par l’image; Setup

Mesh:

Year:  2020        PMID: 33390319     DOI: 10.1016/j.canrad.2020.05.023

Source DB:  PubMed          Journal:  Cancer Radiother        ISSN: 1278-3218            Impact factor:   1.018


  1 in total

1.  Monte Carlo-based software for 3D personalized dose calculations in image-guided radiotherapy.

Authors:  Coralie Le Deroff; Lucie Berger; Julien Bellec; Guillaume Boissonnat; Héléna Chesneau; Sophie Chiavassa; Julie Desrousseaux; Stéphanie Gempp; Olivier Henry; Jimmy Jarril; Delphine Lazaro; Ronan Lefeuvre; Vincent Passal; Fanny Solinhac; Caroline Lafond; Gregory Delpon
Journal:  Phys Imaging Radiat Oncol       Date:  2022-02-26
  1 in total