Percutaneous Image-Guided Anterior Screw Fixation of the Odontoid Process.

Pierre-Alexis Autrusseau1, Damien Heidelberg2, Nicolas Stacoffe2, Danoob Dalili3,4, Roberto Luigi Cazzato5, Guillaume Koch5, Afshin Gangi5, Julien Garnon5.   

Abstract

PURPOSE: To describe the technique of percutaneous image-guided anterior screw fixation of the odontoid process in five patients using hydrodissection of the jugulo-carotid and pre-vertebral spaces. METHODS AND MATERIALS: Between 03/2018 and 03/2020, five patients from two university hospitals underwent a percutaneous image-guided anterior screw fixation of the odontoid process for one pathological fracture, two impending fractures and two traumatic fractures of the dens. Technical success was defined as a satisfactory positioning of the screw in the odontoid. Detailed data with the number and type of needles required, the time to perform hydrodissection, the volume of fluid used, the time for bone access, the size and lengths of the screws used, technical success, complications, clinical outcomes and follow-up were retrospectively assessed.
RESULTS: Technical success was achieved in 100% (5/5 cases), with a mean volume of hydrodissection of 218 ± 8.4 mL (range 210-230). Mean total procedure time was 112 ± 34 min (range 70-160). The lengths of the screws ranged from 30 mm to 55 mm. Additional cementoplasty was performed in the three malignant cases. VAS scores dropped on a 10-point scale from mean 5.8 ± 2.2 pre-procedure to 0.8 ± 0.4 after the procedure. No major complication occurred.
CONCLUSION: Percutaneous image-guided anterior screw fixation of the odontoid process using hydrodissection of the jugulo-carotid and pre-vertebral spaces is technically feasible and seems safe.

Entities:  

Keywords:  C2; Hydrodissection; Odontoid process; Percutaneous; Screw fixation

Mesh:

Year:  2021        PMID: 33388865     DOI: 10.1007/s00270-020-02734-9

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  7 in total

1.  Percutaneous osteosynthesis in the pelvis in cancer patients.

Authors:  Frederic Deschamps; Thierry de Baere; Antoine Hakime; Ernesto Pearson; Geoffroy Farouil; Christophe Teriitehau; Lambros Tselikas
Journal:  Eur Radiol       Date:  2015-08-30       Impact factor: 5.315

Review 2.  Adjunctive Thermoprotection During Percutaneous Thermal Ablation Procedures: Review of Current Techniques.

Authors:  Julien Garnon; Roberto Luigi Cazzato; Jean Caudrelier; Maud Nouri-Neuville; Pramod Rao; Emanuele Boatta; Nitin Ramamurthy; Guillaume Koch; Afshin Gangi
Journal:  Cardiovasc Intervent Radiol       Date:  2018-10-11       Impact factor: 2.740

3.  Anterior retropharyngeal approach to C1 for percutaneous vertebroplasty under C-arm fluoroscopy.

Authors:  Jun-Song Yang; Lei Chu; Fu-Tao Xiao; Dong-Jie Zhang; Yang Wang; Liang Chen; Zhen-Yong Ke; Ding-Jun Hao; Zhong-Liang Deng
Journal:  Spine J       Date:  2014-12-15       Impact factor: 4.166

Review 4.  Management of acute odontoid fractures with single-screw anterior fixation.

Authors:  B R Subach; M A Morone; R W Haid; M R McLaughlin; G R Rodts; C H Comey
Journal:  Neurosurgery       Date:  1999-10       Impact factor: 4.654

5.  Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases.

Authors:  Julien Garnon; Guillaume Koch; Nitin Ramamurthy; Jean Caudrelier; Pramod Rao; Georgia Tsoumakidou; Roberto Luigi Cazzato; Afshin Gangi
Journal:  Cardiovasc Intervent Radiol       Date:  2016-04-05       Impact factor: 2.740

6.  Transoral approach to CT-guided C2 interventions.

Authors:  Arra S Reddy; Diane Dinobile; Juan E Orgeta; Nagamani Peri
Journal:  Pain Physician       Date:  2009 Jan-Feb       Impact factor: 4.965

7.  Balloon kyphoplasty and additional anterior odontoid screw fixation for treatment of unstable osteolytic lesions of the vertebral body C2: a case series.

Authors:  Anna Voelker; Nicolas H von der Hoeh; Christoph-Eckhard Heyde
Journal:  BMC Musculoskelet Disord       Date:  2018-07-27       Impact factor: 2.362

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.