Khoschy Schawkat1, Leo L Tsai2, Adrian Jaramillo-Cardoso2, S Nicolas Paez2, James A Moser3, Corinne Decicco3, Tori Singer3, Jonathan Glickman4, Alexander Brook2, Maria A Manning5, Koenraad J Mortele6. 1. Division of Abdominal Imaging, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University Zurich, Switzerland. Electronic address: k_schawkat@hotmail.com. 2. Division of Abdominal Imaging, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA. 3. Pancreas and Liver Institute, Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA. 4. Department of Pathology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA. 5. American Institute for Radiologic Pathology, Silver Spring, MD, USA; MedStar Georgetown University Hospital, Washington, DC, USA. 6. Dover, MA, USA.
Abstract
PURPOSE: To assess the ability of the ring-enhancing sign and focal necrosis to diagnose adenosquamous carcinoma (ASqC), a variant of pancreatic ductal adenocarcinoma (PDAC), on MRI and CT. METHODS: The following features of ASqC and conventional PDAC were evaluated on CT and MRI: tumor size, location, margins, borders (non-exophytic, exophytic), and T1 signal intensity. Two readers, blinded to histopathology results, rated their confidence in detecting ring-enhancement and focal necrosis (FN) on a 5-point Likert scale on both MRI and CT. Inter-reader agreement was assessed with Cohen's kappa (k). RESULTS: A total of 24 patients were included: eight patients with treatment naïve and histologically proven ASqC (six women, mean age: 63, range: 40-75) and 16 patients with PDAC (eight women, mean age: 67, range: 47-83). Statistically significant differences between ASqC and PDAC were seen in tumor size, location, presence of FN, and ring enhancement (p = 0.01-0.037). The readers were more confident in depicting the key differentiating feature ring-enhancement in ASqC on MRI compared to CT (confidence 1.71 ± 0.49 vs. 0.88 ± 0.35, p = 0.017) with moderate inter-reader agreement (k = 0.46 and 0.5, respectively). FN showed substantial inter-reader agreement on MR and moderate agreement on CT (k = 0.67 and 0.5, respectively). CONCLUSIONS: Compared to CT, MRI depicts ring-enhancement in ASqC with greater reader confidence and FN in ASqC with higher inter-reader agreement. The concurrent presence of these two imaging features should raise high suspicion for ASqC. Published by Elsevier Inc.
PURPOSE: To assess the ability of the ring-enhancing sign and focal necrosis to diagnose adenosquamous carcinoma (ASqC), a variant of pancreatic ductal adenocarcinoma (PDAC), on MRI and CT. METHODS: The following features of ASqC and conventional PDAC were evaluated on CT and MRI: tumor size, location, margins, borders (non-exophytic, exophytic), and T1 signal intensity. Two readers, blinded to histopathology results, rated their confidence in detecting ring-enhancement and focal necrosis (FN) on a 5-point Likert scale on both MRI and CT. Inter-reader agreement was assessed with Cohen's kappa (k). RESULTS: A total of 24 patients were included: eight patients with treatment naïve and histologically proven ASqC (six women, mean age: 63, range: 40-75) and 16 patients with PDAC (eight women, mean age: 67, range: 47-83). Statistically significant differences between ASqC and PDAC were seen in tumor size, location, presence of FN, and ring enhancement (p = 0.01-0.037). The readers were more confident in depicting the key differentiating feature ring-enhancement in ASqC on MRI compared to CT (confidence 1.71 ± 0.49 vs. 0.88 ± 0.35, p = 0.017) with moderate inter-reader agreement (k = 0.46 and 0.5, respectively). FN showed substantial inter-reader agreement on MR and moderate agreement on CT (k = 0.67 and 0.5, respectively). CONCLUSIONS: Compared to CT, MRI depicts ring-enhancement in ASqC with greater reader confidence and FN in ASqC with higher inter-reader agreement. The concurrent presence of these two imaging features should raise high suspicion for ASqC. Published by Elsevier Inc.