| Literature DB >> 33384830 |
Hisae Saito1, Yukio Miyagawa2, Toshiya Endo1,3.
Abstract
BACKGROUND/Entities:
Keywords: Adhesive remnant index; Ceramic bracket; Metal bracket; Plastic bracket; Plastic bracket primer; Shear bond strength
Year: 2020 PMID: 33384830 PMCID: PMC7770309 DOI: 10.1016/j.jds.2020.07.014
Source DB: PubMed Journal: J Dent Sci ISSN: 1991-7902 Impact factor: 2.080
Orthodontic brackets used in this study.
| Bracket | Labeling | Composition | Manufacture | Lot no. | Mean bracket base area (mm2) |
|---|---|---|---|---|---|
| Plastic bracket (PB) | Clear Bracket | Polycarbonate stainless steel slot | Dentsply, Tokyo, Japan | 00010940 | 11.55 |
| Metal bracket (MB) | Victory series | Stainless Steel | 3 M Unitek, CA, USA | HI2QT | 10.23 |
| Ceramic bracket (CB) | Crystaline 7 | Polycrystalline alumina | Tomy, Tokyo, Japan | A2X5 | 13.69 |
Orthodontic adhesive and light-curing unit used in this study.
| Material | Components | Composition | Lot no. | Manufacture |
|---|---|---|---|---|
| BeautiOrtho Bond Ⅱ® | Self-etching primer | Acetone, Water, Bis- GMA, Carboxylic acid monomer, Phop sphoric acid momomer etc. | 081705 | Shofu, Kyoto,Japan |
| Paste Viscos | Bis- GMA, TEGDMA, S - PRG filler, etc. | 101401 | ||
| Plastic bracket primer | MMA, Bis-GMA, etc. | 081702 | ||
| PenCure 2000® | Light-cure | High-power LED | AF0051 | Morita, Tokyo, Japan |
Figure 1The universal testing machine with the specimen holder ring.
Evaluation of adhesive remnant index.
| Score | Description |
|---|---|
| 0 | No adhesive remaining |
| 1 | Less than half of the adhesive remaining |
| 2 | More than half of the adhesive remaining |
| 3 | All adhesive remaining |
Figure 2Stereomicroscope photographs (a-d, x 10) and Scanning electron microscope photographs (e-h, x 22) of the enamel surface showing typical ARI scores of 0–3; a, e the ARI score 0, no adhesive remaining; b, f the ARI score 1, less than half of the adhesive remaining; c, g the ARI score 2, more than half of the adhesive remaining; d, h the ARI score 3, all adhesive remaining.
Shear bond strength (MPa).
| Plastic bracket primer | ||||||
|---|---|---|---|---|---|---|
| Nonapplication (−) | Application (+) | |||||
| Mean | SD | Range | Mean | SD | Range | |
| Plastic bracket (PB) | 5.53 | 1.80 | 3.27–8.82 | 8.75 | 2.46 | 4.77–13.20 |
| Metal bracket (MB) | 9.44 | 2.37 | 6.07–14.07 | 8.87 | 1.82 | 6.09–13.87 |
| Ceramic bracket (CB) | 12.63 | 2.70 | 8.56–18.15 | 13.78 | 3.08 | 7.93–18.56 |
SD indicates standard deviation.
Figure 3Shear bond strength (MPa). PB, MB, and CB indicate plastic, metal, and ceramic brackets, respectively; PB-, MB-, and CB-indicate plastic, metal, and ceramic brackets without the application of plastic bracket primer, respectively; PB+, MB+, and CB + indicate plastic, metal, and ceramic brackets with the application of the plastic bracket primer, respectively. ∗∗p < .01, ∗∗∗p < .001.
Distribution of adhesive remnant index (ARI) scores.
| ARI scores | Comparison between application and nonapplication | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Nonapplication (−) | Application (+) | ||||||||
| 0 | 1 | 2 | 3 | 0 | 1 | 2 | 3 | Mann–Whitney U test | |
| Plastic bracket (PB) | 3 | 7 | 17 | 0 | 4 | 18 | 5 | 0 | <0.01 |
| Metal bracket (MB) | 3 | 10 | 14 | 0 | 2 | 10 | 15 | 0 | NS |
| Ceramic bracket (CB) | 3 | 18 | 6 | 0 | 4 | 21 | 2 | 0 | NS |
| Comparison between brackets types | |||||||||
| Kruskal–Wallis test | <0.05 | <0.01 | |||||||
| Steel–Dwass test | PB- vs MB- | NS | PB + vs MB+ | <0.05 | |||||
| PB- vs CB- | <0.05 | PB + vs CB+ | NS | ||||||
| MB- vs CB- | NS | MB + vs CB+ | <0.01 | ||||||