Using Transthoracic Echocardiography to Predict Fluid Responsiveness after Passive Leg Raising Test: Caution Needed.

R Natesh Prabu1, Amol T Kothekar2.   

Abstract

How to cite this article: Prabu RN, Kothekar AT. Using Transthoracic Echocardiography to Predict Fluid Responsiveness after Passive Leg Raising Test: Caution Needed. Indian J Crit Care Med 2020;24(11):1147-1148.
Copyright © 2020; Jaypee Brothers Medical Publishers (P) Ltd.

Entities:  

Keywords:  Passive leg raising; Transthoracic echocardiography; Velocity-time integral

Year:  2020        PMID: 33384530      PMCID: PMC7751055          DOI: 10.5005/jp-journals-10071-23646

Source DB:  PubMed          Journal:  Indian J Crit Care Med        ISSN: 0972-5229


We read with interest the article by El-Nawawy et al.,[1] on the accuracy of passive leg raising test (PLR) in the prediction of fluid responsiveness (FR) in children. The authors have demonstrated the prediction of FR using PLR with reasonable accuracy. The study is of interest since there is a paucity of information on the utility of PLR in children. We would like to raise a couple of concerns. First, performing PLR in infants and small children may be challenging. Unlike adults, these groups of patients may not cooperate for the procedure. The authors have not mentioned if they had to exclude any patient due to non-cooperation or other reasons. In a recent study looking at PLR in infants and children (mean age was 85.8 ± 69.5 months), <40% of patients could complete the PLR protocol.[2] Second, we have concerns regarding the use of transthoracic echocardiography (TTE) to track the changes in velocity-time integral (VTI)/stroke volume (SV). The authors have used the left ventricular outflow tract velocity-time integral (LVOT-VTI) obtained by TTE for measurement of SV/cardiac output (CO) in response to PLR. Based on the results of the study, authors suggest the use of change in stroke volume (ΔSV) ≥10% or change in cardiac index (ΔCI) >8.7% after PLR as a cut-off for identifying fluid responder from non-responders. Cardiac output and SV measurements using VTI obtained by TTE have its limitations apart from being non-continuous.[3] The VTI measurements are subject to individual variation due to various reasons. First, it requires skill to obtain an optimal image in which the ultrasound beam is aligned with cardiac structures especially obtaining the alignment of the Doppler angle parallel to blood flow. Second, it is challenging to maintain the probe in the same position while repeating the measurements during PLR. Any change in hand position during PLR can cause an error that will affect the measurements. Moreover, there can be a change in VTI due to arrhythmias or changes in rate and depth of ventilation and the readings should be measured at the same period of respiration (end-expiration) especially while comparing the results before and after an intervention. The authors have not mentioned about the hand position, period of respiration when the measurement was taken. All these factors have the potential to affect the measurements during PLR confounding its results. The authors mention good intraobserver reliability in three baseline measurements of SV with an average intraclass correlation of 0.93 [95% confidence interval (CI) = 0.91 to 0.95], p < 0.001 in a pilot study. However, when we are looking at serial measurements, knowing the precision and the least significant change (LSC) of VTI between examinations is probably more important. In a study looking specifically at LSC and precision of repeated values by same and different operators, Jozwiak et al.[4] have demonstrated a lack of precision of VTI for assessing the effects of tests predicting preload responsiveness. Jozwiak et al. showed that the LSC was 11% for VTI between two successive examinations performed by the same operator and 14% if two operators performed the examinations. This means that it is difficult for a single operator to identify with precision a change in VTI ≤10% questioning the use of VTI obtained by TTE for the identification of small changes in CO required in PLR. The cut-off values quoted in the study by El-Nawawy et al. (10 and 8.7% for SV change and cardiac index change) are lower than the LSC of VTI limiting its applications. This is a real concern while using VTI-TTE. In conclusion, the lack of precision of VTI values <11% has been demonstrated in adults. In children <5 years where PLR is yet to be established, studies using VTI for PLR should be interpreted with caution due to the limitation of the absence of precision studies of VTI in this age group.
  3 in total

1.  Accuracy of Passive Leg Raising Test in Prediction of Fluid Responsiveness in Children.

Authors:  Ahmed A El-Nawawy; Passant M Farghaly; Hadir M Hassouna
Journal:  Indian J Crit Care Med       Date:  2020-05

2.  What is the lowest change in cardiac output that transthoracic echocardiography can detect?

Authors:  Mathieu Jozwiak; Pablo Mercado; Jean-Louis Teboul; Anouar Benmalek; Julia Gimenez; François Dépret; Christian Richard; Xavier Monnet
Journal:  Crit Care       Date:  2019-04-11       Impact factor: 9.097

Review 3.  Rationale for using the velocity-time integral and the minute distance for assessing the stroke volume and cardiac output in point-of-care settings.

Authors:  Pablo Blanco
Journal:  Ultrasound J       Date:  2020-04-21