Literature DB >> 33383001

Sensitivity and reproducibility enhancement in enzyme immunosorbent assays based on half fragment antibodies.

Vanessa Susini1, Laura Caponi2, Veronica Lucia Rossi3, Antonio Sanesi3, Nadia Romiti2, Aldo Paolicchi2, Maria Franzini2.   

Abstract

The free sulfhydryl groups of the hinge region of monovalent antibody fragments (rIgG) allow the orientation of rIgG on functionalized surfaces in immunosensors. To evaluate the contribution of reduction and orientation on signal enhancement we compared the performance of whole antibodies and their rIgG in ELISA performed on polystyrene or maleimide-functionalized microplates. Monoclonal anti-horseradish peroxidase (anti-HRP) and monoclonal anti-fPSA antibodies (1 mg/mL) were reduced with 2-mercaptoethylamine (53 mM). Western blot confirmed the presence of rIgG as a band at 75 kDa, detectable only by anti-heavy chain but not by anti-light chain antibodies, suggesting a possible folding rearrangement. Using anti-HRP we confirmed the retention of the antigen binding capacity of rIgG. Moreover, we observed a signal enhancement for rIgG even if randomly absorbed on polystyrene [linear regression slope (95%CI): rIgG 0.524 (0.434-0.614), IgG 0.370 (0.430-0.399); P = 0.0016] suggesting that chemical reduction might affect the antigen binding capacity of antibodies. ELISA with anti-fPSA rIgG coated on polystyrene confirmed these observations. Oriented anti-fPSA rIgG on a maleimide surface showed comparable signals to the assay performed on polystyrene for each analyzed concentration of antigen (PANOVA = 0.1980), anyway, with a significant improvement of the repeatability likely providing a more homogeneous capturing surface (SD rIgGmaleimide-rIgGpolystirene: fPSA 0.725 ng/mL:0.74-2.89; 1.45 ng/mL:1.56-8.69; 3.625 ng/mL:3.52-15.03; 7.25 ng/mL:7.78-18.44).
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Half-fragment antibodies; High-sensitive immunoassays; Reduced antibodies

Mesh:

Substances:

Year:  2020        PMID: 33383001     DOI: 10.1016/j.ab.2020.114090

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  2 in total

Review 1.  Advances in Electrochemical and Acoustic Aptamer-Based Biosensors and Immunosensors in Diagnostics of Leukemia.

Authors:  Tibor Hianik
Journal:  Biosensors (Basel)       Date:  2021-05-31

2.  Signal Enhancement in Oriented Immunosorbent Assays: A Balance between Accessibility of Antigen Binding Sites and Avidity.

Authors:  Vanessa Susini; Vanna Fierabracci; Gaia Barria; Lisa Dodoli; Laura Caponi; Aldo Paolicchi; Maria Franzini
Journal:  Biosensors (Basel)       Date:  2021-12-03
  2 in total