| Literature DB >> 33380895 |
Ankica Sekovanić1, Adrijana Dorotić2, Jasna Jurasović1, Daria Pašalić3, Jelena Kovačić1, Sandra Stasenko4, Tatjana Mioč4, Martina Piasek1, Tatjana Orct1.
Abstract
INTRODUCTION: The assessment of circulating miRNAs is challenging and still limited due to their low concentrations, small size and lack of reference values in human biological samples. Pre-amplification of complementary DNAs may facilitate reliable miRNA quantification. The aim of our study was to evaluate the efficacy of pre-amplification as a step to increase the sensitivity of qPCR analysis for five candidate circulating miRNAs presumably related to toxic metals and cigarette smoke exposure: miR-1537, miR-190b, miR-16, miR-21, and miR-146a.Entities:
Keywords: RT-PCR; blood plasma; circulating microRNAs; epigenetics; pre-amplification
Mesh:
Substances:
Year: 2020 PMID: 33380895 PMCID: PMC7745165 DOI: 10.11613/BM.2021.010901
Source DB: PubMed Journal: Biochem Med (Zagreb) ISSN: 1330-0962 Impact factor: 2.313
qPCR analysis results for candidate miRNAs in not preamplified (no PreAMP) and preamplified (PreAMP) plasma samples
| miR-1537 | 5 | 34.7 (32.6-34.9) | 18 | 28.8 (27.2-34.6)* | 6.3 (4.4-6.6) |
| miR-190b | 12 | 34.6 (32.7-35.4) | 19 | 28.8 (26.6-32.4)* | 6.4 (2.1-8.2) |
| miR-16 | 19 | 23.6 (21.2-32.0) | 19 | 16.4 (13.7-25.1)* | 7.0 (5.3-8.6) |
| miR-21 | 19 | 24.1 (21.0-27.3) | 19 | 17.6 (14.5-20.6)* | 6.5 (4.9-7.8) |
| miR-146a | 19 | 26.8 (24.3-32.3) | 19 | 19.5 (17.6-25.8)* | 6.7 (5.3-7.6) |
| miR-1537† | 2 | 35.3 (35.2-35.3) | 17 | 28.7 (26.0-35.4) | 7.2 (6.6-7.7) |
| miR-190b | 13 | 34.0 (33.4-35.3) | 19 | 28.2 (26.6-33.6)* | 6.1 (3.9-8.3) |
| miR-16‡ | 19 | 23.4 (20.9-30.8) | 19 | 16.6 (14.6-24.4)* | 6.7 (4.9-7.5) |
| miR-21 | 19 | 24.5 (23.2-28.9) | 19 | 18.0 (16.0-23.7)* | 6.6 (5.2-7.2) |
| miR-146a | 19 | 26.7 (24.9-32.5) | 19 | 20.1 (18.5-26.6)* | 6.7 (5.9-7.4) |
| Values are presented as median (min-max). CT - cycle threshold. PreAMP - pre-amplification. CT improvement was calculated as difference between individual CT values of No PreAMP and PreAMP samples. *Statistically significant difference (at P < 0.05) between No PreAMP and PreAMP samples obtained by paired t-test. ‡Difference between No PreAMP and PreAMP samples tested by Wilcoxon signed rank test. †Difference between No PreAMP and PreAMP samples were not tested due to a small number of expressed No PreAMP samples. | |||||
Spearman’s correlation coefficients (ρs) for candidate miRNAs ∆CT values between not preamplified (No PreAMP) and preamplified (PreAMP) plasma samples
| miR-1537 | 11.2±2.50 | 12.2±2.20 | 0.20 | 0.423 |
| miR-190b | 10.7±2.52 | 11.3±1.87 | 0.84 | < 0.001 |
| miR-16 | 0.76±1.09 | 0.47±1.09 | 0.96 | < 0.001 |
| miR-21 | - 0.16±1.59 | 0.17±1.64 | 0.94 | < 0.001 |
| miR-146a | 2.9±1.10 | 2.9±1.10 | 0.97 | < 0.001 |
| miR-1537 | 11.4±2.36 | 12.3±2.13 | -0.19 | 0.444 |
| miR-190b | 10.3±2.13 | 10.8 ±1.29 | 0.72 | 0.001 |
| miR-16 | -0.17±0.98 | -0.22±0.98 | 0.87 | < 0.001 |
| miR-21 | 0.64±1.00 | 0.81±1.02 | 0.92 | < 0.001 |
| miR-146a | 3.1±0.60 | 3.1±0.64 | 0.85 | < 0.001 |
| Data are presented as mean ± standard deviation. N = 19 mother-newborn pairs. CT - cycle threshold. ∆CT - normalized CT values. PreAMP - pre-amplification. ρs - Spearman’s correlation coefficients. CT values reported > 35.4 were set as 36. ∆CT were calculated as follows: CT-miRNA – CT-cel-miR-39. P < 0.05 was considered statistically significant. | ||||
Figure 1Intraclass correlation coefficient (ICC) with 95% confidence interval between qPCR miRNA expression levels in not preamplified and premplified maternal and umbilical cord plasma samples. ICC closer to 1 indicates better agreement. Negative confidence interval limits were trimmed at 0. ∆CT - normalized CT values.