Literature DB >> 33379758

All-optical intrinsic atomic gradiometer with sub-20 fT/cm/√Hz sensitivity in a 22 µT earth-scale magnetic field.

A R Perry, M D Bulatowicz, M Larsen, T G Walker, R Wyllie.   

Abstract

In this work we demonstrate a high sensitivity atomic gradiometer capable of operation in earth-field level environments. We apply a light-pulse sequence at four times the Larmor frequency to achieve gradiometer sensitivity <20 fT/cm/Hz at the finite field strength of 22 µT. The experimental timing sequence can be tuned to the field magnitude of interest. Our all-optical scalar gradiometer performs a differential measurement between two regions of a single vapor cell on a 4 cm baseline. Our results pave the way for extensions to operation in higher dimensions, vector sensitivity, and more advanced gradiometers.

Year:  2020        PMID: 33379758     DOI: 10.1364/OE.408486

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  1 in total

1.  A study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding.

Authors:  Richard J Clancy; Vladislav Gerginov; Orang Alem; Stephen Becker; Svenja Knappe
Journal:  Phys Med Biol       Date:  2021-09-03       Impact factor: 4.174

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.