Literature DB >> 33379511

Simultaneous optical coherence tomography and Scheimpflug imaging using the same incident light.

Xiaoran Li, Samuel Lawman, Bryan M Williams, Sicong Ye, Yaochun Shen, Yalin Zheng.   

Abstract

For any single anterior chamber cross-sectional (tomographic) imaging method, there is a practical compromise between image size and image resolution. In order to obtain large field-of-view cross-sectional images of the whole anterior chamber and high-resolution cross-sectional images of the fine corneal layers, measurements by multiple devices are currently required. This paper presents a novel raster scanning tomographic imaging device that acquires simultaneous large field-of-view Scheimpflug (12.5 mm image depth, 50 μm axial resolution in air) and high-resolution spectral domain optical coherence tomography (SD-OCT) (2 mm image depth, 3.7μm axial resolution in air) using the same illuminating photons. For the novel raster scanning 3D Scheimpflug imaging, a tunable lens system together with numerical methods for correcting refraction distortion were used. To demonstrate the capability of simultaneous measurement of both fine corneal layers and whole anterior chambers topology, ex vivo measurements on 12 porcine and 12 bovine eyes were carried out. There is a reasonable agreement in the overall central corneal thicknesses (CCT) obtained from the simultaneous SD-OCT and Scheimpflug measurements. In addition, because the same infrared light beam was used to illuminate the sample, both OCT and Scheimpflug images were taken at the exact same location of a sample simultaneously in a single measurement. This provides a unique method for measuring both the thickness and the refractive index of a sample.

Entities:  

Year:  2020        PMID: 33379511     DOI: 10.1364/OE.405643

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  2 in total

1.  Nondestructive in situ monitoring of pea seeds germination using optical coherence tomography.

Authors:  Xinhua Li; Xingyu Yang; Xiaoran Li; Zhiyi Zhao; Zijian Zhang; Hungyen Lin; Dingming Kang; Yaochun Shen
Journal:  Plant Direct       Date:  2022-07-12

2.  Accuracy of OCT-derived net corneal astigmatism measurement.

Authors:  Clara Llorens-Quintana; Elias Pavlatos; Omkar Thaware; Seema Gupta; Daniel Gradin; Denzil Romfh; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2022-03-01       Impact factor: 3.528

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.