Assessment of microtransducers in anorectal manometry.

R Miller1, D C Bartolo, A M Roe, N J Mortensen.   

Abstract

It has been reported that microtransducer-tipped catheters (transducer) produce reliable reproducible measurements which correlate well with water-filled balloon systems. Maximum resting pressure (MRP) and maximum voluntary contraction pressures (MVC) were compared using a standard station pull-through technique in 12 patients. There was a poor correlation for both MRP: microballoon, 115 cmH2O (60-160 cmH2O); transducer 60 (20-110), r = 0.62, P less than 0.05, and MVC: microballoon, 202 (60-375); transducer, 175 (60-210), r = 0.42, n.s. To determine whether this was due to radial variation in pressures measured by the transducer, we studied a further 39 patients with both systems. At each station, transducer measurements were made at each of four quadrants. We found better correlation for MRP: microballoon, 100 (40-175); transducer, 66 (34-120), r = 0.72, P less than 0.001, and MVC: microballoon, 225 (55-650); transducer, 180 (50-470), r = 0.87, P less than 0.001, but a significant radial variation for the transducer where rotation reduced MRP pressure measurements by 21 per cent (0-600 per cent), and MVC 17 per cent (0-76 per cent). Moreover there was a significant difference between anterior and posterior MRP in the upper anal canal, anterior 35 (5-80) versus posterior 25 (10-60), P less than 0.05. These results account for the poor correlation between random positioning of the microtransducer-tipped catheter and indicate that radial orientation must be taken into account.

Entities:  

Mesh:

Year:  1988        PMID: 3337949     DOI: 10.1002/bjs.1800750115

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  6 in total

Review 1.  The usefulness of tests in anorectal disease.

Authors:  T G Parks
Journal:  World J Surg       Date:  1992 Sep-Oct       Impact factor: 3.352

Review 2.  Anal manometry.

Authors:  R J Felt-Bersma; S G Meuwissen
Journal:  Int J Colorectal Dis       Date:  1990-08       Impact factor: 2.571

3.  Prolonged anorectal manometry and external anal sphincter electromyography in ambulant human subjects.

Authors:  D Kumar; D Waldron; N S Williams; C Browning; M R Hutton; D L Wingate
Journal:  Dig Dis Sci       Date:  1990-05       Impact factor: 3.199

Review 4.  The pelvic floor in health and disease.

Authors:  A A Shelton; M L Welton
Journal:  West J Med       Date:  1997-08

5.  Flatus-related colorectal and anal motor events.

Authors:  G Bassotti; U Germani; A Morelli
Journal:  Dig Dis Sci       Date:  1996-02       Impact factor: 3.199

6.  Functional outcome after Swenson's operation for Hirshsprung's disease.

Authors:  Nabil A Gad El-Hak; Mohamed M El-Hemaly; Emad H Negm; Ehab A El-Hanafy; Magdy H Abdel Messeh; Hala H Abdel Bary
Journal:  Saudi J Gastroenterol       Date:  2010 Jan-Mar       Impact factor: 2.485

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.