Literature DB >> 33379138

Electrochemical Immunosensor for the Early Detection of Rheumatoid Arthritis Biomarker: Anti-Cyclic Citrullinated Peptide Antibody in Human Serum Based on Avidin-Biotin System.

Somasekhar R Chinnadayyala1, Sungbo Cho1,2.   

Abstract

Rheumatoid arthritis (RA) is a chronic autoimmune disease that produces a progressive inflammatory response that leads to severe pain, swelling, and stiffness in the joints of hands and feet, followed by irreversible damage of the joints. The authors developed a miniaturized, label-free electrochemical impedimetric immunosensor for the sensitive and direct detection of arthritis Anti-CCP-ab biomarker. An interdigitated-chain-shaped microelectrode array (ICE) was fabricated by taking the advantage of microelectromechanical systems. The fabricated ICE was modified with a self-assembled monolayer (SAM) of Mercaptohexanoic acid (MHA) for immobilization of the synthetic peptide bio-receptor (B-CCP). The B-CCP was attached onto the surface of SAM modified ICE through a strong avidin-biotin bio-recognition system. The modified ICE surface with the SAM and bio-molecules (Avidin, B-CCP, Anti-CCP-ab and BSA) was morphologically and electrochemically characterized. The change in the sensor signal upon analyte binding on the electrode surface was probed through the electrochemical impedance spectroscopy (EIS) property of charge-transfer resistance (Rct) of the modified electrodes. EIS measurements were target specific and the sensor response was linearly increased with step wise increase in target analyte (Anti-CCP-ab) concentrations. The developed sensor showed a linear range for the addition of Anti-CCP-ab between 1 IU mL-1 → 800 IU mL-1 in phosphate buffered saline (PBS) and Human serum (HS), respectively. The sensor showed a limit of detection of 0.60 IU mL-1 and 0.82 IU mL-1 in the PBS and HS, respectively. The develop bio-electrode showed a good reproducibility (relative standard deviation (RSD), 1.52%), selectivity and stability (1.5% lost at the end of 20th day) with an acceptable recovery rate (98.0% → 101.18%) and % RSD's for the detection of Anti-CCP-ab in spiked HS samples.

Entities:  

Keywords:  anti-cyclic citrullinated peptide antibodies; electrochemical impedance spectroscopy; immunosensor; interdigitated chain shaped microelectrode array; rheumatoid arthritis

Mesh:

Substances:

Year:  2020        PMID: 33379138      PMCID: PMC7795521          DOI: 10.3390/s21010124

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  33 in total

1.  Anti-Fab aptamers for shielding virus from neutralizing antibodies.

Authors:  Darija Muharemagic; Mahmoud Labib; Shahrokh M Ghobadloo; Anna S Zamay; John C Bell; Maxim V Berezovski
Journal:  J Am Chem Soc       Date:  2012-10-09       Impact factor: 15.419

2.  Preparation, characterization, resistance to protein adsorption, and specific avidin-biotin binding of poly(amidoamine) dendrimers functionalized with oligo(ethylene glycol) on gold.

Authors:  Chi Ming Yam; Maxence Deluge; David Tang; Amit Kumar; Chengzhi Cai
Journal:  J Colloid Interface Sci       Date:  2005-10-13       Impact factor: 8.128

3.  Relationship between rheumatoid factor isotypes and IgG anti-cyclic citrullinated peptide antibodies.

Authors:  Troy D Jaskowski; Harry R Hill; Katherine L Russo; Gabriella Lakos; Zoltan Szekanecz; Marius Teodorescu
Journal:  J Rheumatol       Date:  2010-06-01       Impact factor: 4.666

4.  A comparative study of IgG second- and third-generation anti-cyclic citrullinated peptide (CCP) ELISAs and their combination with IgA third-generation CCP ELISA for the diagnosis of rheumatoid arthritis.

Authors:  Lisiane Maria Enriconi dos Anjos; Ivanio Alves Pereira; Eleonora d 'Orsi; Andrea Piette Seaman; Rufus Watson Burlingame; Edelton Flavio Morato
Journal:  Clin Rheumatol       Date:  2008-09-16       Impact factor: 2.980

5.  Comparison of chemiluminescence enzyme immunoassay (CLEIA) with ELISA for the determination of anti-cyclic citrullinated peptide antibodies.

Authors:  Ryo Tanaka; Masao Takemura; Masao Sato; Yasunori Yamada; Takahito Nakagawa; Takuro Horibe; Masato Hoshi; Hirofumi Otaki; Hiroyasu Ito; Mitsuru Seishima; Katsuji Shimizu
Journal:  Clin Chim Acta       Date:  2009-10-07       Impact factor: 3.786

6.  Au nanoparticle decorated graphene nanosheets for electrochemical immunosensing of p53 antibodies for cancer prognosis.

Authors:  Reda Elshafey; Mohamed Siaj; Ana C Tavares
Journal:  Analyst       Date:  2016-04-25       Impact factor: 4.616

7.  Label-free and direct detection of C-reactive protein using reduced graphene oxide-nanoparticle hybrid impedimetric sensor.

Authors:  Ajay Kumar Yagati; Jae-Chul Pyun; Junhong Min; Sungbo Cho
Journal:  Bioelectrochemistry       Date:  2015-10-09       Impact factor: 5.373

Review 8.  Meta-analysis: diagnostic accuracy of anti-cyclic citrullinated peptide antibody for juvenile idiopathic arthritis.

Authors:  Yan Wang; Fengyan Pei; Xingjuan Wang; Zhiyu Sun; Chengjin Hu; Hengli Dou
Journal:  J Immunol Res       Date:  2015-02-19       Impact factor: 4.818

9.  A portable optical-fibre-based surface plasmon resonance biosensor for the detection of therapeutic antibodies in human serum.

Authors:  Luigi Zeni; Chiara Perri; Nunzio Cennamo; Francesco Arcadio; Girolamo D'Agostino; Mario Salmona; Marten Beeg; Marco Gobbi
Journal:  Sci Rep       Date:  2020-07-07       Impact factor: 4.379

10.  Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode.

Authors:  Somasekhar R Chinnadayyala; Jinsoo Park; Young Hyo Kim; Seong Hye Choi; Sang-Myung Lee; Won Woo Cho; Ga-Yeon Lee; Jae-Chul Pyun; Sungbo Cho
Journal:  Sensors (Basel)       Date:  2019-12-16       Impact factor: 3.576

View more
  4 in total

1.  Deciphering the Disaggregation Mechanism of Amyloid Beta Aggregate by 4-(2-Hydroxyethyl)-1-Piperazinepropanesulfonic Acid Using Electrochemical Impedance Spectroscopy.

Authors:  Hien T Ngoc Le; Sungbo Cho
Journal:  Sensors (Basel)       Date:  2021-01-25       Impact factor: 3.576

Review 2.  The Role of Peptides in the Design of Electrochemical Biosensors for Clinical Diagnostics.

Authors:  Patrick Severin Sfragano; Giulia Moro; Federico Polo; Ilaria Palchetti
Journal:  Biosensors (Basel)       Date:  2021-07-23

3.  Controlled, partially exfoliated, self-supported functionalized flexible graphitic carbon foil for ultrasensitive detection of SARS-CoV-2 spike protein.

Authors:  Muhammad Adeel; Kanwal Asif; Vincenzo Canzonieri; Hasi Rani Barai; Md Mahbubur Rahman; Salvatore Daniele; Flavio Rizzolio
Journal:  Sens Actuators B Chem       Date:  2022-02-21       Impact factor: 7.460

Review 4.  Towards Multiplexed and Multimodal Biosensor Platforms in Real-Time Monitoring of Metabolic Disorders.

Authors:  Sung Sik Chu; Hung Anh Nguyen; Jimmy Zhang; Shawana Tabassum; Hung Cao
Journal:  Sensors (Basel)       Date:  2022-07-12       Impact factor: 3.847

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.