Literature DB >> 33378728

A comparative study of prostate PTV margins for patients using hydrogel spacer or rectal balloon in proton therapy.

Zhong Su1, Randal Henderson2, Romaine Nichols2, Curtis Bryant2, Bradford Hoppe2, William Mendenhall2, Nancy Mendenhall2.   

Abstract

PURPOSE: To compare the planning target volume (PTV) margins needed for prostate patients who have used hydrogel spacer or rectal balloon during proton treatments.
METHOD: Total of 190 prostate patients treated with proton therapy during 2017 were selected for this study. Of these patients, 96 had hydrogel spacer injection and 94 patients had only rectal balloons insertion. All patients had implanted gold markers inside the prostate for daily target alignment. Post-treatment radigraphs were obtained to evaluate prostate intrafraction motion. The systematic and random components of patient setup residual error and prostate intrafraction motion error were obtained. PTV margins were calculated using the van Herk formula for both patient groups.
RESULTS: For setup residual error, the mean values in the superior-inferior (SI) direction and the variances in the left-right (LR) direction were statistically different between the two groups. For intrafraction motion, there were significant differences of the mean values in the SI direction and of the variances in both LR and anterior-posterior (AP) directions. The population PTV margins for hydrogel spacer group were 2.6 mm, 3.3 mm, and 1.6 mm in LR, SI, AP directions, respectively. For the rectal balloon group, the PTV margins were 2.1 mm, 3.1 mm, and 2.0 mm in LR, SI, AP directions, respectively.
CONCLUSION: Statistically significant differences were observed in the patient setup and prostate intrafraction motion errors of the two patient groups. However, under the current protocol of bladder preparation and daily marker-based x-ray image-guidance, population PTV margins were comparable between the two patient groups.
Copyright © 2020 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Hydrogel spacer; Intrafraction motion; PTV margins; Prostate; Rectal balloon

Mesh:

Substances:

Year:  2020        PMID: 33378728     DOI: 10.1016/j.ejmp.2020.11.033

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  2 in total

1.  Dosimetric Advantages of Silicone-Filled Vaginal Spacers in Pediatric Proton Therapy.

Authors:  Ozgur Ates; Li Zhao; David Sobczak; Chia-Ho Hua; Matthew J Krasin
Journal:  Int J Part Ther       Date:  2022-05-06

2.  Impact of intrafraction changes in delivered dose of the day for prostate cancer patients treated with stereotactic body radiotherapy via MR-Linac.

Authors:  Jennifer Dang; Vickie Kong; Winnie Li; Inmaculada Navarro; Jeff D Winter; Victor Malkov; Alejandro Berlin; Charles Catton; Jerusha Padayachee; Srinivas Raman; Padraig Warde; Peter Chung
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2022-08-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.